HP Integrity NonStop H-Series User Manual
Page 86

Appendix A
WVP Event Analyzer Plug-in User Guide V01 – 536989-001
- 86 -
Recovery: Depends on the Filename and Error number.
NSEVNTA 151
<Program Name> <Function Name>: Error Reading for file <Filename> <Error Number>
Relating to function or activity: Admin interface program communicating with the EACOLL process.
Cause: Occurs when the admin interface program is unable to send update data to the EACOLL
process.
Effect: The parameters updated in the operation will not be reflected by in working of the EACOLL
process.
Recovery: Restart the EACOLL process.
NSEVNTA 171
<Program Name> <Function Name>: <Informational message>
Relating to function or activity: Either Admin or UI functionality or EACOLL process.
Cause: Informational message to be given out.
Effect: None.
Recovery: None.
NSEVNTA 550
<Program Name> <Function Name>: Read access error to Collector log files or Collector. Error
<Error Number>
Relating to function or activity: EACOLL process collecting and analyzing the information for a given
collector or log file.
Cause: EACOLL process does not have read access permissions for the Collector or Log file
specified as the event source .
Effect: The particular run of the EACOLL process will not computing any information.
Recovery: Correct the read access permission or change the event source(s).
NSEVNTA 558
<Program Name> <Function Name>: Problem with adding Event source <event-source>
Relating to function or activity: EACOLL process collecting and analyzing the information for a given
collector or log file.
Cause: Invalid Collector or Log file specified as the event source.
Effect: The particular run of the EACOLL process will not computing any information.
Recovery: Correct the event source from the EA Admin interface.
Possible Warning and Informational EMS Messages