HP Integrity NonStop H-Series User Manual

Page 86

Advertising
background image

Appendix A

WVP Event Analyzer Plug-in User Guide V01 – 536989-001

- 86 -

Recovery: Depends on the Filename and Error number.

NSEVNTA 151

<Program Name> <Function Name>: Error Reading for file <Filename> <Error Number>

Relating to function or activity: Admin interface program communicating with the EACOLL process.

Cause: Occurs when the admin interface program is unable to send update data to the EACOLL
process.

Effect: The parameters updated in the operation will not be reflected by in working of the EACOLL
process.

Recovery: Restart the EACOLL process.

NSEVNTA 171

<Program Name> <Function Name>: <Informational message>

Relating to function or activity: Either Admin or UI functionality or EACOLL process.

Cause: Informational message to be given out.

Effect: None.

Recovery: None.

NSEVNTA 550

<Program Name> <Function Name>: Read access error to Collector log files or Collector. Error
<Error Number>

Relating to function or activity: EACOLL process collecting and analyzing the information for a given
collector or log file.

Cause: EACOLL process does not have read access permissions for the Collector or Log file
specified as the event source .

Effect: The particular run of the EACOLL process will not computing any information.

Recovery: Correct the read access permission or change the event source(s).

NSEVNTA 558

<Program Name> <Function Name>: Problem with adding Event source <event-source>

Relating to function or activity: EACOLL process collecting and analyzing the information for a given
collector or log file.

Cause: Invalid Collector or Log file specified as the event source.

Effect: The particular run of the EACOLL process will not computing any information.

Recovery: Correct the event source from the EA Admin interface.

Possible Warning and Informational EMS Messages

Advertising
This manual is related to the following products: