1-3 error & advisory messages (pop-up events) – HP Integrity NonStop H-Series User Manual

Page 87

Advertising
background image

Appendix A

WVP Event Analyzer Plug-in User Guide V01 – 536989-001

- 87 -

NSEVNTA 150

<Program Name> <Function Name>: Loading events from log file <Filename>

<Program Name> <Function Name>: Loading events from collector for the date range specified

<Program Name> <Function Name>: Getting %d previous days' worth of events

<Program Name> <Function Name>: Beginning daily scan of events

<Program Name> <Function Name>: Daily Run Time Updated

Relating to function or activity: The EACOLL process will generate informational messages with event
number 150 at the time of the daily scans or one-time scans of the EMS logs or log files.

Cause: These can occur either if events are loaded using the one-time load function (admin

section 3-

1-2-7

); or if the daily run time is updated from admin

section 3-1-2-1

; or right before the daily scan

begins.

Effect: NA

Recovery: NA

[Back to TOC]

5-1-3 Error & Advisory Messages (Pop-up Events)

This section lists all Pop-up Events that can be generated specifically from Event Analyzer application
conditions.

Possible Critical Pop-up Messages

If a database interaction error (on a procedure call) occurs, an EMS event is generated as explained
in the previous section. In addition, the user will be shown the same error message in a pop-up
message window if the error occurs while the user is on one of the EA or EA Admin screens.

Possible Warning and Informational Pop-up Messages


Function or activity: EA Main Screen events severity filter

At least one of Normal and Critical checkboxes need to be checked!

Cause: Both, Normal and Critical checkboxes left unchecked.

Recovery: Check the Normal, Critical or both checkboxes. If none are checked, there won’t be any
events to return.

At least one of Non-Action and Action checkboxes need to be checked!

Cause: Both, Non-Action and Action checkboxes left unchecked.

Recovery: Check the Non-Action, Action or both checkboxes. If none are checked, there won’t be any