Access attributes and permitted operations

Specified as S-VOL

Specified as P-VOL

Write Operations
from Hosts

Read Operations
from Hosts

Access Attribute

Yes

Yes

Yes

Yes

Read/Write

No

Depends on the replication
software

No

Yes

Read-only

No

Depends on the replication
software

No

No

Protect

No

Yes

Yes

Yes

Read/Write and
S-VOL disable

Access attribute restrictions

Some restrictions apply when you use the following P9500 products or functions on a volume that
has an access attribute assigned to it.

LUN Expansion (LUSE)

When creating a LUSE volume, you cannot combine volumes that do not have the read/write
access attribute. You can, however, assign an access attribute other than read/write to the
resulting LUSE volume.

You cannot release a LUSE volume that does not have the read/write access attribute.

Virtual LUN

You cannot convert into spaces volumes that do not have the read/write attribute.

You cannot initialize customized volumes that do not have the read/write attribute.

RAID Manager

You can use RAID Manager to make some Data Retention settings. You can view some of the
RAID Manager settings in the Data Retention user interface.

When viewing the Data Retention window, another user might be using RAID Manager to
change an access attribute of a volume. If the RAID Manager user changes an access attribute
of a volume when you are viewing the Data Retention window, you will be unable to change
the access attribute of the volume by using Data Retention. If you attempt to change the access
attribute of the volume by using the Data Retention, an error occurs. If the error occurs, click
File > Refresh All on the menu bar of the Remote Web Console main window, and then retry
changing the access attribute of the volume.

Automatic starting products

If any software that can start automatically is enabled, you must do one of the following:

Perform Data Retention operations when the program is not running.

Cancel the setting of the program start time.

Some software is likely to start automatically at the time specified by the user. For example, if an
Auto LUN user or a Performance Monitoring user specifies the time for starting the monitor, the
monitor will automatically start at the specified time.

Access attributes work flow