Edit ports confirm window, Selected ports table – HP XP P9500 Storage User Manual

Page 401

Advertising
background image

Description

Item

Only 10 Gbps can be specified for the FCoE port. Auto cannot be specified
for the FCoE port.

Select the address of the selected port.

Address (Loop ID)

Select whether a fabric switch is set to ON or OFF. Only ON can be specified
for the FCoE port.

Fabric

Select the topology.

Connection Type

FC-AL: Fibre channel arbitrated loop

P-to-P (point-to-point). Only P-to-P can be specified for the FCoE port.

CAUTION:

Some fabric switches require that you specify point-to-point

topology. If you enable a fabric switch, check the documentation for the
fabric switch to determine whether your switch requires point-to-point
topology.

Edit Ports Confirm window

Confirm proposed settings, name the task, and then click Apply. The task will be added to the
execution queue.

Selected Ports table

Description

Item

The identifier of the port.

Port ID

The attribute of the port indicating I/O flow.

Attribute

Initiator: Issues I/O commands to a target port when I/O is executed
between storage systems with Continuous Access Synchronous, and so
on.

Target: Receives I/O commands from a host.

RCU Target: Receives I/O commands from an initiator when I/O is
executed between storage systems with Continuous Access Synchronous,
and so on.

External: Issues I/O commands to a target port of an external storage
system with External Storage.

Edit Ports wizard 401

Advertising