Error Contents

Error Code (SSB2)

Increase the THP V-VOL capacity after finishing
operations on your storage system, such as the

The operation was rejected because the
configuration was being changed by SVP or

0xb902

Virtual LUN operation or a maintenance

Remote Web Console, or because the THP

operation. See Caution in

“Requirements for

increasing THP V-VOL capacity” (page 78)

.

V-VOL capacity was going to be increased by
another instance of the RAID Manager.

Increase the THP V-VOL capacity after the
specified volume is placed online with the OS
which supports EAV.

The operation was rejected because the
specified volume is placed online with the OS
which does not support EAV (Extended Address
Volume).

0xaf22

Specify a capacity so that the pool reservation
rate will not be exceeded.

The operation was rejected because the total
THP V-VOL capacity exceeded the pool

0xaf24

reservation rate after the capacity was
increased.

Check the emulation type of the specified THP
V-VOL.

The operation to increase capacity cannot be
performed on the specified THP V-VOL.

0xaf25

Specify a capacity so that the maximum number
of cache management devices will not be
exceeded.

The operation was rejected because of lack of
cache management devices due to increased
capacity.

0xaf26

Makes sure that the volume is a THP V-VOL.

Because the specified volume was not a THP
V-VOL, the operation was rejected.

0xaf29

To increase capacity, specify the correct
capacity that does not exceed the value

Because the specified capacities are invalid or
exceeded the value immediately below LDEV

0xaf2a

immediately below LDEV Capacity in the Expand

Capacity in the Expand Virtual Volumes
window, the operation was rejected.

Virtual Volumes window. See the conditions for
increasing THP V-VOL capacity in

“Requirements

for increasing THP V-VOL capacity” (page 78)

.

Re-execute the operation after a brief interval.

Because the specified volume operation was not
finished, the operation was rejected.

0xaf2b

Confirm the value immediately below LDEV
Capacity in the Expand Virtual Volumes
window.

Because the shared memory capacity is not
enough to increase the specified capacity, the
operation was rejected.

0xaf2c

Wait until formatting of the specified volume is
finished, or see

“Using Thin Provisioning or

Because the specified THP V-VOL was used by
other software or was being formatted, the
operation was rejected.

0xaf2e

Smart Tiers with other P9500 products”
(page 80)

and confirm whether the THP V-VOL

is used with software in which that the THP
V-VOL capacity cannot be increased.

Re-execute the operation after the microcode is
replaced.

Because the THP V-VOL capacity was increased
when the microcode was replaced, the
operation was rejected.

0xaf2f

Re-execute the raidcom extend ldev
command without specifying the -cylinder
option.

Because the raidcom extend ldev
command was executed with specifying the
-cylinder

option to the THP V-VOL for the

open system, the operation was rejected.

0x0b2b

Errors when operating RAID Manager (Data Retention, SSB1:2E31/B9BF/B9BD)

Description

Error Code (SSB2)

The command cannot be executed because user authentication is not performed.

9100

The setting failed because the specified volume does not exist.

B9BD

The specified volume is a command device.

B9C2