When browsing to Systems Insight Manager using Microsoft Internet Explorer 6.0.3790.0 on
Windows 2003, the billboard in lower corner of the Home page is blank.
Solution: Enable Play Animations in Web Pages in Internet Explorer. To access this, select
Tools

→Internet Options→Advanced, and then select Play Animations in Web Pages under the

Multimedia section.
-------------------------------------------------------------
If you receive a Page Not Found browser error when launching HP Insight Control performance
management tools from within Systems Insight Manager, the CMS name link might not have resolved
correctly on the network.
Solution: Note the name being used in the browser window, verify that the name resolves on the
network, and that it is not being affected by any proxy settings in the browser.
-------------------------------------------------------------
When you try to browse to the SMH on the same Linux system that Systems Insight Manager is
installed, you might receive multiple browser warning messages.
Solution: Complete the following:
1.

Open a terminal window.

2.

At the command prompt, enter: /etc/opt/hp/hpsmh/certs /opt/hp/hpsmh/certs

3.

Press the Enter key.

4.

At the command prompt, enter: service hashed restart

5.

Press the Enter key.

Central Management Server

Resource-intensive applications such as HP Insight Control performance management have sometimes
encountered problems working with large numbers of systems. In an effort to improve the stability
of the CMS, Systems Insight Manager now imposes a limit of 2000 systems on the information
that is provided to these applications. This limit can be changed, if necessary, by adding a new
property named MaxNodesViaSOAP to globalsettings.props and setting it to the desired
number of systems. Setting MaxNodesViaSOAP to a negative number disables the limit checking.
In some cases, setting this limit to a number greater than 2,000, or disabling the limit, can results
in errors, including the possibility of Systems Insight Manager hanging or crashing.
-------------------------------------------------------------
When you cannot access Systems Insight Manager on a Windows system using a full DNS host
name, your Windows DNS; configuration is not set properly.
Solution: There are several reasons and workarounds for this:

The TCP/IP Settings for your Network Connection are not configured properly.
HP recommends the following workaround:
1.

On the CMS, open the Control Panel, and select Network Connections

→Local Area

Connection Settings

→Internet Protocol (TCP/IP)→Properties→Advanced.

2.

Select the DNS tab.

3.

Be sure that DNS suffix for this connection contains the full DNS suffix for the system.

4.

Be sure both the Register this connection's address in DNS and the Use this connection's
DNS suffix in DNS registration checkboxes are selected.

The System name for the CMS is not configured properly.
HP recommends the following workaround:
1.

On the CMS, open the Control Panel and select System.

2.

Click Network Identification.

3.

Click Properties or Change next to the Rename this computer or Join a domain field.

4.

In the dialog box, click More.