Setting up hp-ux managed systems – HP Systems Insight Manager User Manual

Page 27

Advertising
background image

Setting up HP-UX servers to be managed by Systems Insight Manager

Procedure 3 Setting up HP-UX managed systems

1.

Understand the basic managed system software for HP-UX.

For HP-UX, the following software, shown with minimum recommended versions, is required
for essential Systems Insight Manager functionality to operate. This software is installed by
default as part of the latest HP-UX 11i v2 and 11i V3 operating environments, but it might
need to be installed or updated on HP-UX 11i v1 or older HP-UX 11i v2 environments.

T1471AA HP-UX Secure Shell

B8465BA HP

WBEM Services

for HP-UX

OpenSSL

This WBEM Services bundle contains basic system instrumentation displayed in the Systems
Insight Manager Property pages, supporting collection and reporting by Systems Insight
Manager inventory functionality. To maximize the value of Systems Insight Manager for
properties, inventory, and events, see

http://www.hp.com/go/hpsim/providers

for the latest

WBEM Services bundle.

If iCap information is desired, also install:

B9073BA version 08.01.01 iCAP for HP-UX

2.

Ensure the managed system software is installed.

To verify that the minimum required software is installed, log in to the remote system, and run
the following command:

$ swlist –l bundle T1471AA B8465BA OpenSSL

To verify that the optional providers and HP System Management Homepage are installed,
run commands such as:

$ swlist –l bundle LVMProvider WBEMP-LAN-00 SysMgmtWeb SysFaultMgmt

OnlineDiag

3.

Acquire and install the managed system software if not previously installed.

The SSH and WBEM bundles are included on the HP-UX Operating Environment and
Application Release media, as well as part of the Systems Insight Manager HP-UX depot
downloaded from

http://h18013.www1.hp.com/products/servers/management/hpsim/

dl_hpux.html

.

For the WBEM providers, see

http://h18013.www1.hp.com/products/servers/management/

hpsim/dl_hpux.html

.

After you have obtained the depots containing the software, you can install then from the
managed system:

$ swinstall –s <depot_location> OpenSSL

NOTE:

B8465BA and B9073BA version 08.01.01 depends on OpenSSL, so you must install

OpenSSL first.

$ swinstall –s <depot_location> T1471AA

$ swinstall –s <depot_location> B8465BA

$ swinstall –s <depot_location> <names of WBEM providers being

installed>

After you have verified that the correct management software is installed on your managed systems,
continue to Chapter 4

“Credentials” (page 32)

to finish the configuration from the Systems Insight

Manager user interface.

Setting up HP-UX servers to be managed by Systems Insight Manager

27

Advertising