Security, Tasks, Tools – HP Systems Insight Manager User Manual

Page 169: Issue when running tools on hp-ux 11.31, System page

Advertising
background image

Insight Manager Installdir>/config/globalsettings.props

file or by running the

CLI command: mxglobalsettings --a EnhancedReportsLogicalFonts=<font name>
where font name can be Dialog or SansSerif. The default value is Dialog.

Security

If Systems Insight Manager is installed after SMH is installed, the SMH 2048-bit key pair is replaced
with the Systems Insight Manager 1,024-bit key pair.

System Page

When WBEM protocol is enabled, incorrect drive information is displayed in the Logical Volume
section in the Performance tab for a blade server.
Solution: To view the accurate drive information, disable the WBEM protocol and enable SNMP
protocol. To do so, select Options

→Protocol Settings→Global Protocol Settings.

Tasks

The Initial ProLiant Support Pack Install task does not work on Windows 2000 target systems.
Likewise, the install portion of the Configure or Repair Agents tool does not work on Windows
2000 systems.
Solution: If the HP Version Control Agent is present on these target systems, then the Install Software
and Firmware tool can be used to distribute agents, Support Packs and other components to
Windows 2000 systems.

Tools

The message /tmp/Acmd42947.bat[26]: /usr/dt/bin/dtterm: not found might
appear when running the following tools on HP-UX 11.31:

Retrieve Bastille Configuration file

Deploy Bastille Configuration

Consolidated Logging Wizard

Configuration Synchronization Wizard

To eliminate this problem:
1.

Remove the above tools using the CLI command mxtool -r -t <tool name>.

2.

Edit the tool definition XML files, replacing instances of dtterm and hpterm with xterm.
The above-mentioned tools can be found in the following TDef files:

security_patch_check.xml

clog_windows.xml

3.

Add the tools again using mxtool -a -f <TDef file name>

4.

Run the tool.

Retrieve Bastille Configuration file

Deploy Bastille Configuration

Consolidated Logging Wizard

Configuration Synchronization Wizard

Solution: To eliminate this problem:

Procedure 42 Issue when running tools on HP-UX 11.31

1.

Remove the above tools using the CLI command mxtool -r -t <tool name>.

2.

Edit the tool definition XML files, replacing instances of dtterm and hpterm with xterm.
The above-mentioned tools can be found in the following TDef files:

security_patch_check.xml

Security

169