Bn-dev, Output ), Utput – Red Lion PAX2S User Manual

Page 14: Arameters, Setpoint output parameters ( setpnt ), Output, Select, Assign, Setpnt, Action

Advertising
background image

14

OUtPUt

SEtPNt

SELECt

S1

SPt

Setpoint

Select

ASSIGN

NONE

S

n

Setpoint

Assignment

SEtPNt

100

S

n

Setpoint

Value

ACtION

NO

S

n

Setpoint

Action

bn-dEU

0

S

n

Band/

Deviation

Value

HYStEr

2

S

n

Hysteresis

Value

t-ON

0.0

S

n

On Time

Delay

t-OFF

0.0

S

n

Off Time

Delay

n = Setpoint Number (1-4)

LOGIC

nor

S

n

Output

Logic

StndbY

NO

S

n

Setpoint

Standby

Operation

rESEt

Auto

S

n

Reset

Action

Annun

nor

S

n

Setpoint

Annunciator

Color

NO CHG

S

n

Line 1

Change Color

Pro

OUtPUt

Pro

NO

F1

F2

P

D

O

uTpuT

p

arameTers

(OUtPUt)

SETPOINT SELECT

S1

S2

S3

S4

Select the Setpoint output to be programmed. The “Sn” in the following

parameters will reflect the chosen setpoint number. After the chosen setpoint is

completely programmed, the display returns to the Setpoint Select menu. Repeat

steps for each setpoint to be programmed.

The number of outputs available is setpoint output card dependent (2 or 4). If

no output card is installed, programming is still available for all 4 setpoints. This

allows the Line 1 color change feature to provide a visual indication when a

setpoint value has been reached, even if no setpoint output is being used.

SETPOINT ASSIGNMENT

NONE

rEL

GrOSS

tOtAL

Selects the meter value to be used to trigger the Setpoint Alarm. The rEL

setting will cause the setpoint to trigger off of the relative (net) input value. The

relative input value is the absolute input value plus the Display Tare (Offset)

Value. The GrOSS setting will cause the setpoint to trigger off of the gross

(absolute) input value. The gross input value is based on the Input (Analog)

module dSP and INP entries.

SETPOINT ACTION

NO

Ab-HI

Ab-LO

AU-HI

AU-LO

dE-HI

dE-LO

bANd

bNdIn

totLo

totHi

Enter the action for the selected setpoint (alarm output). See Setpoint Alarm

Figures for a visual detail of each action. The Setpoint Actions that pertains to

the total is only active when the Setpoint Assignment is set to tOtAL.

NO

= No Setpoint Action

Ab-HI

= Absolute high, with balanced hysteresis

Ab-LO

= Absolute low, with balanced hysteresis

AU-HI

= Absolute high, with unbalanced hysteresis

AU-LO

= Absolute low, with unbalanced hysteresis

dE-HI

= deviation high, with unbalanced hysteresis

dE-LO

= deviation low, with unbalanced hysteresis

bANd

= Outside band, with unbalanced hysteresis

bNdIn

= Inside band, with unbalanced hysteresis

totLo

= Lower 6 digits of 9 digit Totalizer, with unbalanced hysteresis

totHi

= Upper 6 digits of 9 digit Totalizer, with unbalanced hysteresis

SETPOINT VALUE

-199999

to

999999

Enter desired setpoint alarm value. Setpoint values can also be entered in the

Display Mode during Program Lockout when the setpoint is programmed as
Entr

in the Display (Line 2) Access parameters. The decimal point position is

determined by the Setpoint Assignment value.

BAND/DEVIATION VALUE

-199999

to

999999

This parameter is only available in band and deviation setpoint actions. Enter

desired setpoint band or deviation value. When the Setpoint Action is

programmed for Band, this value can only be a positive value.

HYSTERESIS VALUE

1

to

65000

Enter desired hysteresis value. See Setpoint Alarm Figures for visual

explanation of how setpoint alarm actions (balanced and unbalanced) are

affected by the hysteresis. When the setpoint is a control output, usually balanced

hysteresis is used. For alarm applications, usually unbalanced hysteresis is used.

For unbalanced hysteresis modes, the hysteresis functions on the low side for

high acting setpoints and functions on the high side for low acting setpoints.

Note: Hysteresis eliminates output chatter at the switch point, while time delay

can be used to prevent false triggering during process transient events.

SELECt

S1

SPt

ASSIGN

NONE

Sn

ACtION

NO

Sn

SEtPNt

100

Sn

bn-dEV

0

dn

HYStEr

2

Sn

SETPOINT OUTPUT PARAMETERS (SEtPNt)

This section details the programming for the setpoints. To have output capabilities, a setpoint Plug-in card needs to be installed into the PAX2S (see Ordering

Information). Depending on the card installed, there will be two or four setpoint outputs available. If no output card is installed, programming for the setpoints is still

available. An Exchange Parameter Lists feature for setpoint values is explained in User Input programming.

The Setpoint Assignment and Setpoint Output Action determine certain setpoint feature availability. The Setpoint Parameter Availability chart illustrates this.

OUTPUT SELECT

SEtPNt

ANALOG

Select the Setpoint or Analog output to be programmed. The Analog output selection

only appears if an analog output plug-in card is installed in the meter.

OUtPUt

SEtPNt

Setpoint Action dependent

Advertising