Scroll, Units, Code – Red Lion PAX2S User Manual

Page 19: No 1, Off label cust fact lb-fac l1-fac lb-cst lb ln1, Label, Cust, Fact, Lb-cst, Lb-fac

Advertising
background image

19

SELECTION

DESCRIPTION

r-2

Reset Setpoint output 2

r-3

Reset Setpoint output 3

r-4

Reset Setpoint output 4

r-34

Reset Setpoint outputs 3 & 4

r-234

Reset Setpoint outputs 2, 3 & 4

r-ALL

Reset all Setpoint outputs

Print

Print Request

LINE 2 DISPLAY SCROLL ENABLE/TIME

NO

1

to

15

seconds

If Line 2 Display Scrolling is desired, set the scroll time in seconds.

LINE 2 UNITS MNEMONIC(S)

OFF

LAbEL

CUSt

FACt

Lb-FAC

L1-FAC

Lb-CSt

Lb Ln1

Select the mode for Line 2 Units Mnemonic(s). See LINE 2 UNITS

MNEMONIC DIAGRAM for programming details.

SELECTION

MODE

DESCRIPTION

OFF

OFF

No Line 2 mnemonics shown.

LAbEL

LABEL

Single programmable mnemonic shown as a

separate item in the Line 2 Display loop. No

individual mnemonics are shown with the other

Line 2 Display values.

CUSt

CUSTOM

Individual Custom programmable mnemonics

shown with each value in the Line 2 Display loop.

FACt

FACTORY

Individual Factory default mnemonics shown with

each value in the Line 2 Display loop.

Lb-CSt

LABEL &

CUSTOM

A programmable mnemonic shown as a separate

item in the Line 2 Display loop. Also, individual

Custom programmable mnemonics shown with

each value in the Line 2 Display loop.

Lb-FAC

LABEL &

FACTORY

A programmable mnemonic shown as a separate

item in the Line 2 Display loop. Also, individual

Factory default mnemonics shown with each

value in the Line 2 Display loop.

Lb Ln1

LINE 1

INDEXED

LABELS

Individual programmable mnemonics, indexed to

the Line 1 Display value, are shown as a

separate item in the Line 2 Display loop. These

same mnemonics are also shown with each

value in the Line 2 Display loop.

L1-FAC

LINE 1

INDEXED

LABELS &

FACTORY

Individual programmable mnemonics, indexed to

the Line 1 Display value, are shown as a

separate item in the Line 2 Display loop. Also,

individual Factory default mnemonics are shown

with each value in the Line 2 Display loop.

The characters available for the programmable modes include:

A b C d E F G H I J k L M N O P q r S t U W Y Z 0 1
2 3 4 5 6 7 8 9 a c e g h i

m

n o u

w

- = [ ] / ° _ blank

PROGRAMMING SECURITY CODE

000

to

250

To activate either the Parameter or Hidden Parameter display loops, a security

code (1-250) must be entered. If a “0” security code is programmed, pressing the

P key takes you directly to the Full Programming Mode.

The Security Code determines the programming mode and the accessibility

of programming parameters. This code can be used along with the Program

Mode Lock-out (PLOC) in the User Input Function parameter (Input [User]

module).

Two programming modes are available. Full Programming Mode allows all

parameters to be viewed and modified. Parameter display loop mode provides

access to those selected parameters, that can be viewed and/or modified without

entering the Full programming mode.

The following chart indicates the levels of access based on various CodE and

User Input PLOC settings.

SECURITY

CODE

USER INPUT

CONFIGURED

USER INPUT

STATE

WHEN P KEY IS

PRESSED

FULL PROGRAMMING

MODE ACCESS

0

not

PLOC

———— Full Programming

Immediate Access

0

PLOC

Not Active Full Programming

Immediate Access

0

PLOC

Active

Enter Parameter

Display Loop

No Access

>0

not

PLOC

———— Enter Parameter

Display Loop

After Parameter

Display Loop with

correct code # at

COdE

prompt.

>0

PLOC

Not Active Full Programming

Immediate Access

>0

PLOC

Active

Enter Parameter

Display Loop

After Parameter

Display Loop with

correct code # at

COdE

prompt.

ScroLL

NO

Ln2

UNItS

FACt

Ln2

Two character spaces are required to display this character.

COdE

0

dSP

P

LINE 2 UNITS MNEMONIC DIAGRAM (9-DIGITS)

Edit

NO

P

Edit

CSt

NO

P

UNItS

Ln2

OFF

COdE

Ln2

000

UNItS

Ln2

LAbEL

Edit

YES

UNItS

Ln2

CUSt

Edit

INPUt

Unit 1

1

Unit 2

2

Unit 9

9

Edit

LO

P

P

P

P

Unit 1

1

Unit 2

2

Unit 9

9

P

P

P

P

P

P

Unit 1

1

Unit 2

2

Unit 9

9

P

P

P

P

Lb

Lb

Lb

Lb

Lb

CSt

CSt

INP

INP

INP

Lo

Lo

Lo

(Unit 3 thru 8)

(Unit 3 thru 8)

(Unit 3 thru 8)

(returns to currently selected value)

P

UNItS

Ln2

FACt

Lb-CSt

Lb-CSt

Lb-FAC

Lb Ln1

L1-FAC

F1

F2

F1

F2

F1

F2

GrOSS
tArE
tOtAL
HI

Advertising