Color, D-lev, D-cont – Red Lion PAX2S User Manual

Page 17: Select, Scroll, Units, Disply, Disply ), Isplay, Arameters

Advertising
background image

17

LINE 1 DISPLAY COLOR

GrEEN

rEd

OrANGE

Enter the desired Display Line 1 and programmable Units Display color.

DISPLAY INTENSITY LEVEL

0

to

4

Enter the desired Display Intensity Level (0-4) by using the arrow keys. The

display will actively dim or brighten as the levels are changed. This parameter

can also be accessed in the Parameter display loop when enabled.

DISPLAY CONTRAST LEVEL

0

to

15

Enter the desired Display Contrast Level (0-15) by using the arrow keys. The

display contrast / viewing angle will actively adjust up or down as the levels are

changed. This parameter can also be accessed in the Parameter display loop

when enabled.

LINE 1 DISPLAY VALUE SELECT/ENABLE

NO YES

Enter YES to select which values will be shown on the Line 1 display. A sub-

menu provides Yes/No selection for each available Line 1 value. Values set to
YES

in the sub-menu will be displayable on Line 1.

DISPLAY

DESCRIPTION

FACTORY

INPUt

Input

YES

GrOSS

Gross (absolute)

NO

tArE

Tare

NO

tOtAL

Total

NO

HI

Max value

NO

LO

Min value

NO

S1

Setpoint 1

NO

S2

Setpoint 2

NO

S3

Setpoint 3

NO

S4

Setpoint 4

NO

LINE 1 DISPLAY SCROLL ENABLE/TIME

NO

1

to

15

seconds

If Line 1 Display Scrolling is desired, set the scroll time in seconds.

LINE 1 UNITS MNEMONIC(S)

OFF

LAbEL

CUSt

FACt

Select the mode for Line 1 Units Mnemonic(s). See LINE 1 UNITS

MNEMONIC DIAGRAM for programming details.

SELECTION

MODE

DESCRIPTION

OFF

OFF

No Line 1 mnemonic shown.

LAbEL

LABEL

Single programmable mnemonic

shown for all Line 1 values.

CUSt

CUSTOM

Custom programmable mnemonics

shown for each Line 1 value.

FACt

FACTORY

Factory default mnemonics shown for

each Line 1 value.

The characters available for the programmable modes include:
A b C d E F G H I J K L M N O P Q R S t U V W Y Z 0 1
2 3 4 5 6 7 8 9

a c e g h i

m

n o q r u

w

- = [ ] / ° _ blank

Color

GrEEN

Ln1

d-LEV

4

dSP

d-Cont

7

dSP

SELECt

NO

Ln1

ScroLL

NO

Ln1

UNItS

OFF

Ln1

Two character spaces are required to display this character.

d

isplay

p

arameTers

(dISPLY)

LINE 1 PARAMETERS (LINE 1)

This section details programming for the Line 1 (Top Line) Display. The Input, Gross, Tare, Total, Maximum (HI) and Minimum (LO) capture values and setpoints

can be shown on the Line 1 display. The 3-digit Units mnemonic characters can be used to indicate which Line 1 display value is shown. Standard mnemonics are

available for Setpoints 1-4. Standard or custom mnemonics are available for all other Line 1 values.

Main Display Loop

In the Main display loop, the selected values can be consecutively read on Line 1 by activating a user input or function key programmed as SEL L1. Each time the

user input/function key is activated, Line 1 display will change to the next enabled Line 1 display value. Line 1 can also be programmed for Scroll, which will cause

Line 1 to automatically scroll through all of the selected Line 1 display values.

DISPLAY SELECT

LINE 1

LINE 2

SCNdrY

tOtAL

Select the Display to be programmed.

dISPLY

LINE 1

Color

GrEEN

Ln1

Line 1 Display

Color

d-LEV

4

dSP

Display

Intensity

SELECt

NO

Ln1

Line 1

Display Values

d-Cont

7

dSP

Display

Contrast

ScroLL

NO

Ln1

Line 1 Scroll

Enable/Time

UNItS

OFF

Ln1

Line 1 Units

Mnemonics

dISPLY

LINE 1

Selected Line 1 Color Displayed

Pro

dISPLY

Pro

NO

F1

F2

P

D

P

LINE 1 UNITS MNEMONIC DIAGRAM (3-DIGITS)

Edit

123

NO

P

Edit

Ln1

NO

P

123 = Current Units Mnemonic

P

UNItS

Ln1

OFF

dISPLY

LINE 1

UNItS

Ln1

LAbEL

Edit

123

YES

UNItS

Ln1

CUSt

UNItS

Ln1

FACt

Edit

123

INPUt

Unit 1

123

1

Unit 2

123

2

Unit 3

123

3

Edit

123

LO

P

P

P

P

Unit 1

123

1

Unit 2

123

2

Unit 3

123

3

P

P

P

P

P

P

Unit 1

123

1

Unit 2

123

2

Unit 3

123

3

P

P

P

P

(returns to currently selected value)