16

SETPOINT ANNUNCIATOR

nor

rEv

FLASH

OFF

The nor mode displays the corresponding setpoint annunciators of “on”

alarm outputs. The rEv mode displays the corresponding setpoint annunciators

of “off” alarms outputs. The FLASH mode flashes the corresponding setpoint

annunciators of “on” alarm outputs. The OFF mode disables display setpoint

annunciators.

LINE 1 CHANGE COLOR

NO CHG

GrEEN

OrANGE

rEd

GrnOrG

rEdOrG

rEdGrn

LINE 1

This parameter allows the Line 1 Display to change color, or alternate

between two colors, when the alarm is activated. When multiple alarms are

programmed to change color, the highest numbered active alarm (S4-S1)

determines the display color.

The NO CHG selection will maintain the color displayed prior to the alarm

activation. The LINE 1 selection sets the display to the Display (Line 1)

Color (Color).

Annun

nor

Sn

Color

NO CHG

Sn

tYPE

4-20

AnL

ASSIGN

NONE

AnL

ANALOG

0

LO

ANALOG

10000

HI

Analog

Output Type

Analog Output

Assignment

Analog Low

Scale Value

Analog High

Scale Value

OUtPUt

ANALOG

UPdAtE

0.0

AnL

Analog Update

Time

Pro

OUtPUt

Pro

NO

F1

F2

P

D

ANALOG OUTPUT PARAMETERS (ANALOG)

This section is only accessible with the optional PAXCDL Analog card installed (see Ordering Information).

ANALOG OUTPUT TYPE

4-20 0-10 0-20

Enter the analog output type. For 0-20 mA or 4-20 mA use terminals 18 and

19. For 0-10 V use terminals 16 and 17. Only one range can be used at a time.

ANALOG OUTPUT ASSIGNMENT

NONE

rEL

GrOSS

tOtAL

HI

LO

S1

S2

S3

S4

Enter the source for the analog output to retransmit:

NONE

= Manual Mode operation. (See Serial RLC Protocol in the

Communications Port module).

rEL

=

Relative (net) Input Value. The Relative Input Value is the

Gross (Absolute) Input Value that includes the Display

Tare (Offset) Value.

GrOSS

= Gross (Absolute) Input Value. The Gross Input Value is

based on the Input (Analog) module dSP and INP entries.

tOtAL

= Totalizer Value

HI

=

Maximum Display Value

LO

=

Minimum Display Value

S1

-S4 = Setpoint Values

ANALOG LOW SCALE VALUE

-199999

to

999999

Enter the Display Value that corresponds to 0 mA (0-20 mA) , 4 mA (4-20

mA) or 0 VDC (0-10 VDC).

ANALOG HIGH SCALE VALUE

-199999

to

999999

Enter the Display Value that corresponds to 20 mA (0-20 mA) , 20 mA (4-20

mA) or 10 VDC (0-10 VDC).

ANALOG UPDATE TIME

0.0

to

10.0

Enter the analog output update rate in seconds. A value of 0.0 allows the

meter to update the analog output at the ADC Conversion Rate.

tYPE

4-20

AnL

ASSIGN

NONE

AnL

ANALOG

0

LO

ANALOG

10000

HI

UPdAtE

0.0

AnL

Advertising