Power Cable Connection

In order to use this transceiver for fi xed station operation, you will need a
separate 13.8 V DC power supply that must be purchased separately. The
recommended current capacity of the power supply is 13 A.

Note: Do not plug the DC power supply into an AC outlet until you make all connections.

1 Ensure that the transceiver and DC power supply are both OFF.

2 Connect the DC power cable to the regulated DC power supply and ensure

that the polarities are correct (Red: positive, Black: negative).

Use the supplied DC power cable to connect the transceiver to a regulated
power supply. Do not directly connect the transceiver to an AC outlet.

Do not substitute the cable with smaller gauge wires.

3 Connect the DC power cable to the transceiver.

Press the connectors fi rmly together until the locking tab clicks.

Note: For your transceiver to fully exhibit its performance capabilities, we recommend using an
optional PS-60 (20.5 A, 25% duty cycle) power supply.

Black (

‒) cable

Red (+) cable

DC power cable

Fuse holder

Fuse holder

Regulated DC power supply