4 personal computer and serial printer cable, 5 bnc for the vcr trigger and alarm reset, 6 relay and alarm connectors – Videotec SM328B User Manual

Page 13

Advertising
background image

2.2.3.10

Connecting cable between matrix and Santec dome on Aux line

Matrix TX

RJjack1

Santec Dome

RS485A

white

TX+

RS485B

yellow

TX-

2.2.4

Personal computer and serial printer cable

Connect the personal computer or serial printer using a standard complete male/female 9-pin serial cable

(serial extension).

2.2.5

BNC for the VCR Trigger and Alarm Reset

The VCR trigger is described in section 4.1.1 Trigger signal, page 25.

The Alarm Reset trigger is described in section 3.4.14.3 External Alarm Reset Trigger, page 22.

2.2.6

Relay and alarm connectors

Pin

DB25 A

DB25 B

CATEGORY

Pin

DB25 A

DB25 B

CATEGORY

1

Alarm 1

Alarm 17

14

Alarm 14

Alarm 30

2

Alarm 2

Alarm 18

15

Alarm 15

Alarm 31

ALARMS

3

Alarm 3

Alarm 19

16

Alarm 16

Alarm 32

4

Alarm 4

Alarm 20

17

Common al.

Common al.

5

Alarm 5

Alarm 21

18

Relay 1A

Relay 5A

6

Alarm 6

Alarm 22

ALARMS

19

Relay 1B

Relay 5B

7

Alarm 7

Alarm 23

20

Relay 2A

Relay 6A

8

Alarm 8

Alarm 24

21

Relay 2B

Relay 6B

RELAYS

9

Alarm 9

Alarm 25

22

Relay 3A

Relay 7A

10

Alarm 10

Alarm 26

23

Relay 3B

Relay 7B

11

Alarm 11

Alarm 27

24

Relay 4A

Relay 8A

12

Alarm 12

Alarm 28

25

Relay 4B

Relay 8B

13

Alarm 13

Alarm 29

2.2.6.1

Electrical specifications of the alarms

Warning! Do not power the alarm contacts! The sensors (or the alarm control centre) must

supply a dry contact.

2.2.6.2

Electrical specifications for the relays

Switching power: 10W max

Switching voltage: 50 VAC/DC max.

Switching current: 0.5A max

2. System installation

Page 11/65

MNVCSM328A_0438

Advertising