2.3.3.2

Special settings

DIP switch

1

2

3

4

5

6

7

8

Meaning

-

-

-

-

off

-

-

-

The matrix ignores commands from the PC, if any

-

-

-

-

ON

-

-

-

The PC can control the matrix

-

-

-

-

-

off

off

off

Normal position

-

-

-

-

-

ON

-

-

Restore settings

-

-

-

-

-

-

ON

ON Updating firmware

2.3.3.3

Restoring the settings

It is possible to restore the factory settings for the matrix using the DIP switch. All previous parameter

settings will be lost. If possible we advise downloading the setting to the PC before proceeding with the
reset, to simplify any future reinstallation.

1. Switch off the matrix

2. Set dip 6 to ON

3. Switch on the matrix and wait until the presentation screen disappears

4. Set dip 6 to OFF.

2.3.3.4

Updating the firmware

The matrix firmware (program) can be updated when necessary.

When the firmware is updated the matrix setup is not erased. After updating, however, we advise checking

all the previous parameter settings are still correct, and if not we advise proceeding to reset the matrix and
then re-configure all the parameters.

1. Switch off the matrix

2. Connect the Personal Computer using the serial cable

3. Set dips 7 and 8 to ON

4. Run the update program

5. When updating is finished, close the program then switch off the matrix

6. Set dips 7 and 8 to OFF

7. Switch on the matrix and make sure it is set up correctly.