2.3 Jumpers and DIP switch

2.3.1

Opening the matrix

Inside the matrix there are two jumpers (JP1 and JP2, behind the Aux connectors) for inserting the RS485
load, one DIP switch (SW1, near the backup battery in the centre of the board) and a backup battery:

Warning! The operations described below are carried out with the matrix cover removed. Take

great care to prevent the risk of electric shock.

2.3.2

RS485 load

Jumpers on the Aux lines

To comply with the standard, the RS485 communication lines must be terminated at the ends to prevent

signal reflection.

On the Aux A and Aux B auxiliary communication lines the load can be inserted (jumper in the LOAD
position) or excluded (jumper in the NOLOAD position).

JPA is the jumper on the Aux A line, JPB is the jumper on the Aux B line.

2.3.3

DIP switch

To prevent faulty operation of the system, do not make DIP switch settings that are not included

in the following tables.

2.3.3.1

Protocol and baud rate

DIP switch

1

2

3

4

5

6

7

8

Protocol

Baud rate

Notes

off

off

off

off

-

-

-

-

Macro

38400

default

ON

off

off

off

-

-

-

-

Macro

19200

off

ON

off

off

-

-

-

-

Macro

9600

ON

ON

off

off

-

-

-

-

Macro

1200