Videotec SM328B User Manual

Page 20

Advertising
background image

closed periods during the week, extra holidays and periods when the building is closed.

While the parameters are being edited the bottom lines will show the permitted values for the parameters
actually being modified.

3.4.7.1

Weekdays

For each day of the week (Monday, Tuesday etc.) it is possible to define a maximum of four time bands
during which the system is considered open. At all times outside these 4 periods the system is considered
closed.

It is possible to copy the parameter settings for a particular day using the

0

key so as to simplify

insertion when the periods are the same (from Monday to Friday for example). To cancel a line press

-

when inserting the numeric value.

3.4.7.2

Holidays

Holidays are defined as feast days that are not included as normal non-working days (e.g. Sundays).

For each day key in the numerical values as requested. If the value inserted is not valid, the previous
setting will not be changed. To cancel a line press

-

when inserting a numerical value.

It is possible to define a maximum of 16 individual holidays over the year.

3.4.7.3

Closed Periods

These are periods when the building is closed (for holidays) and are defined by (inclusive) initial and final

dates.

It is possible to define a maximum of 8 closed periods over the year.

3.4.8

Time

For Time it is possible to make the following settings:

current time

format (24-hour international or 12-hour English with AM/PM)

position and display (or not)

parameters for automatic management of summer and solar time periods.

3.4.8.1

Summer and solar time

Summer/solar time can be managed in 2 ways:

Automatic: a number of parameters should be inserted (Last Sunday in March for example). It is
possible to select pre-set parameters for certain zones by pressing the

2

key.

Warning! The pre-set parameters are determined by legislation, which may be changed without prior notice.

To change the parameters press the corresponding number and select the desired value with

+

and

-

; confirm the selection with

E

.

Date/Time: used when the date and time of the start and end of summer time is known.

Warning! The Date/Time type parameters are valid for only one year and should then be reset to the correct values as

and when necessary.

3.4.9

Enabling the keyboards

(Are some of the keyboards enabled only during certain timebands?)

Each keyboard is identified by a number from 1 to 8, which is set at the keyboard level, independently of

the matrix connector to which the keyboard is connected.

Warning! The number should not be repeated within the group of keyboards connected to a system: the

presence of keyboards with the same ID number will make it impossible for them to control the matrix.

3. Setup

Page 18/65

MNVCSM328A_0438

Advertising