Campbell Scientific CR3000 Micrologger User Manual
Page 191

Section 7. Installation
191
Example:
Probe: Water Content
Power Usage:
• Quiescent: 0.25 mA
• Measurement: 120 mA
• Measurement Time: 15 s
• Active: 66 mA
• Timeout: 15 s
Probes 1, 2, 3, and 4 are connected to SDI-12 / Control Port 1.
The time line in table Example Power Usage Profile for a Network of SDI-12
Probes
(p. 191)
shows a 35-second power-usage profile example.
For most applications, total power usage of 318 mA for 15 seconds is not
excessive, but if 16 probes were wired to the same SDI-12 port, the resulting
power draw would be excessive. Spreading sensors over several SDI-12 terminals
will help reduce power consumption.
Table 30. Example Power Usage Profile for a Network of SDI-12 Probes
Sec Command
All
Probes
Awake
Time
Out
Expires
1 mA
2 mA
3 mA
4 mA
Total
mA
1
1M!
Yes 120
66 66 66
318
2
120 66 66 66 318
•
• • • • •
•
• • • • •
•
• • • • •
14
120 66 66 66 318
15
Yes 120 66 66 66 318
16
1D0!
Yes 66 66 66 66
264
17
66 66 66 66 264
•
• • • • •
•
• • • • •
•
• • • • •
29
66 66 66 66 264
30
Yes 66 66 66 66 264
31
0.25 0.25 0.25 0.25 1
•
• • • • •
•
• • • • •
•
• • • • •
35
0.25 0.25 0.25 0.25 1