Section 10. Troubleshooting

441

 

Charging Regulator with Solar-Panel Test

Disconnect any wires attached to the 12V and G (ground) terminals on the PS100 or CH100 charging regulator. Unplug any batteries. Connect the solar panel to the two
CHG terminals. Polarity of inputs does not matter. Only the solar panel should be connected. Set the charging-regulator power switch to OFF.

NOTE

This test assumes the solar panel has an unregulated output.

 

Solar Panel Test

Set a voltmeter to measure DC voltage. Measure solar panel output
across the two solar-panel leads by placing a voltmeter lead on one
CHG terminal, and the other lead on the other CHG terminal. Is the
output 17 to 22 Vdc?

No

Remove the solar-panel leads from the
charging circuit. Measure solar-panel
output across the two leads. Is the
output > 0 Vdc?

No

The solar panel is damaged
and should be repaired or
replaced.

Yes

Yes

Is the voltage ≥ 17 Vdc?

No

There may not be enough
sunlight to perform the test,
or the solar panel is
damaged.

Yes

Yes

Reconnect the power source
(transformer / solar panel) to the CHG
terminals on the charging regulator.
Measure the voltage between the two
CHG terminals. Is the voltage ≥ 17 Vdc
/ Vac?

No

 

5-kΩ Load Test

1) Place a 5-kΩ resistor between a 12V terminal and a G (ground)
terminal on the charging regulator.
2) Switch the power switch to ON.
3) Measure the DC voltage across the resistor.
Is the measured voltage 13.3 to 14.1 V?

No

Measure the voltage between the two
pins in a battery-connection receptacle.
Is the voltage 10.0 to 15.5 Vdc?

No

Yes

Yes

See Adjusting Charging Voltage

(p.

443)

to calibrate the charging regulator,

or return the charging regulator to
Campbell Scientific for calibration.

50-Ω Load Test

1) Switch the power switch to

OFF

.

2) Disconnect the power source (transformer / solar panel).
3) Remove the 5-kΩ resistor
4) Place a 50-Ω, 1-Watt resistor between a

12V

terminal and a

G

(ground) terminal on the charging regulator.
5) Reconnect the power source and then switch the power switch to

ON

.

7) Measure the voltage across the ends of the resistor.
Is the voltage 13.0 to 14.0 Vdc (13.3 if circuit just adjusted)?
8) Switch the power switch to

OFF

.

NOTE

The resistor will get HOT in just a few seconds. After

measuring the voltage, switch the power switch to

OFF

and allow

the resistor to cool before removing it.

No

With the charging regulator still under
load, measure the voltage between the
two CHG terminals. Is the voltage >
15.5 Vdc?

Yes

Obtain Repair

Authorization

The charging regulator is
damaged and should be
repaired or replaced.

Yes

No

Test Completed

The charger is functioning
properly. Remove the 50-Ω
resistor.

There may not be enough sunlight to
perform the test.

 

Advertising