Figure 117: devconfig deployment | advanced tab – Campbell Scientific CR3000 Micrologger User Manual

Page 365

Advertising
background image

Section 8. Operation

365

 

Figure 117: DevConfig Deployment | Advanced tab

Table 89. PakBus-LAN Example Datalogger-Communications Settings

Software→

Device Configuration Utility (DevConfig)

Tab→

Deployment

Sub-Tab→

Datalogger

ComPort Settings

Advanced

Setting→

PakBus Adr

COM1

COM2

Is Router

Sub-Setting→

Baud Rate

Neighbors

1

Baud Rate

Neighbors

1

Datalogger ↓

Begin:

End:

Begin:

End:

CR3000_1

1

115.2K Fixed

2

2

115.2K Fixed

3

4

Yes

CR3000_2

2

115.2K Fixed

1

1

Disabled

No

CR3000_3

3

115.2K Fixed

1

1

115.2K Fixed

4

4

Yes

CR3000_4

4

115.2K Fixed

3

3

Disabled

No

1

Setup can be simplified by setting all neighbor lists to Begin: 1 End: 4.

 

Advertising