Section 7. Installation

241

 

200

Table 39. Parameters for Analog Burst Mode (601 to 2000 Hz)

CRBasic

Analog

Voltage

Input

Parameters

Description when in Burst Mode

Destination

A variable array dimensioned to store all measurements from a single channel.
For example, the command,

Dim

FastTemp(500)

dimensions array

FastTemp()

to store 500 measurements (one second of data at

500 Hz, one-half second of data at 1000 Hz, etc.)
The dimension can be any integer from

1

to

65535

.

Repetitions

The number of measurements to make on a single channel. This number
usually equals the number of elements dimensioned in the

Destination

array.

Valid arguments range from

1

to

65535

.

Voltage Range

The analog input voltage range to be used during measurements. No change
from standard measurement mode. Any valid voltage range can be used.
However, ranges appended with 'C' cause measurements to be slower than
other ranges.

Single-Ended
Channel

The single-ended analog input channel number preceded by a dash (

-

). Valid

arguments range from

-1

to

-28

.

Differential
Channel

The differential analog input channel number preceded by a dash (

-

). Valid

arguments range from

-1

to

-14

.

Measure Offset

No change from standard measurement mode.

False

allows for faster

measurements.

Measurements
per Excitation

Must equal the value entered in

Repetitions

Reverse Ex

No change from standard measurement mode. For fastest rate, set to

False.

Rev Diff

No change from standard measurement mode. For fastest rate, set to

False.

Settling Time

Sample interval in µs. This argument determines the measurement rate.
500 µs interval = 2000 Hz rate
750 µs interval = 1333.33 Hz rate

Integ

Ignored if set to an integer.

_50Hz

and

_60Hz

are valid for AC rejection but are

seldom used in burst applications.

Multiplier

No change from standard measurement mode. Enter the proper multiplier.
This is the slope of the linear equation that equates output voltage to the
measured phenomena. Any number greater or less than

0

is valid.

Offset

No change from standard measurement mode. Enter the proper offset. This is
the Y intercept of the linear equation that equates output voltage to the
measured phenomena.

 

7.8.13 String Operations

String operations are performed using CRBasic string functions, as listed in String
Functions

(p. 504).