4 procedure: (short cut steps 12 to 16), Figure 18: short cut outputs tab – Campbell Scientific CR3000 Micrologger User Manual
Page 50

Section 4. Quickstart Tutorial
50
11. Outputs displays the list Selected Sensors on the left and data storage tables,
under Selected Outputs, on the right.
Figure 18: Short Cut outputs tab
4.2.4.4 Procedure: (Short Cut Steps 12 to 16)
12. By default, there are two tables initially available. Both tables have a Store
Every field and a along with a drop-down list from which to select the time
units. These are used to set the time interval when data are stored.
13. Only one table is needed for this tutorial, so Table 2 can be removed. Click
tab, then click Delete Table.
14. Change the name of the remaining table to OneMin, and then change the
interval to 1 minute (Store Every 1 Minutes).
15. Adding a measurement to the table is done by selecting the measurement
under Selected Sensors, and then clicking one of the processing buttons in the
center of the window.
16. Apply the Average function to the Batt_Volt, PTemp_C, and Temp_C
measurements.