3 enclosure, 1 enclosure installation, Enclosure – Campbell Scientific T.Weather T107 Toro Weather Station User Manual
Page 24: Enclosure installation, 6. t107 instrumentation mounted on the et tower, N 2.3
T107 Weather Station
2.3 Enclosure
The weather station datalogger, power supply, sensor connection panel,
communications devices, and data retrieval peripherals are mounted in the ET
enclosure. Refer to Appendix C.1, Enclosure, for a labeled, exploded view of
the enclosure.
FIGURE 2-6. T107 Instrumentation Mounted on the ET Tower
2.3.1 Enclosure Installation
1. Mount the ET enclosure on the ET Tower as shown in FIGURE 2-7.
a. Remove the front lid. Remove the connector cover from the back of
the ET enclosure by loosening the Phillips screw at the bottom of the
cover.
b. Loosen the mounting bracket bolts on the back of the enclosure wide
enough to slide over the pole. Slide the enclosure over the pole.
Position the enclosure so it faces east for northern latitudes or west
for southern latitudes. The top of the enclosure should be 2 – 2.5 cm
(3/4 to 1 in) above the top of the pole (see FIGURE 2-7).
ET Enclosure
Tipping Bucket
Rain Gage
Pyranometer
Crossarm
Met One 034B
Wind Set
Radiation
Shield
Lightning
Rod
Ground
Rod
16