3 enclosure, 1 enclosure installation, Enclosure – Campbell Scientific T.Weather T107 Toro Weather Station User Manual

Page 24: Enclosure installation, 6. t107 instrumentation mounted on the et tower, N 2.3

Advertising
background image

T107 Weather Station

2.3 Enclosure

The weather station datalogger, power supply, sensor connection panel,

communications devices, and data retrieval peripherals are mounted in the ET

enclosure. Refer to Appendix C.1, Enclosure, for a labeled, exploded view of

the enclosure.

FIGURE 2-6. T107 Instrumentation Mounted on the ET Tower

2.3.1 Enclosure Installation

1. Mount the ET enclosure on the ET Tower as shown in FIGURE 2-7.

a. Remove the front lid. Remove the connector cover from the back of

the ET enclosure by loosening the Phillips screw at the bottom of the

cover.

b. Loosen the mounting bracket bolts on the back of the enclosure wide

enough to slide over the pole. Slide the enclosure over the pole.

Position the enclosure so it faces east for northern latitudes or west

for southern latitudes. The top of the enclosure should be 2 – 2.5 cm

(3/4 to 1 in) above the top of the pole (see FIGURE 2-7).

ET Enclosure

Tipping Bucket

Rain Gage

Pyranometer

Crossarm

Met One 034B

Wind Set

Radiation

Shield

Lightning

Rod

Ground

Rod

16

Advertising