T107 Weather Station
TABLE 4-3. Gill WindSonic Diagnostic Codes
Diagnostic
Status
Comment
0
Okay
All okay
1
Axis 1 Failed
Insufficient samples, possible path obstruction
2
Axis 2 Failed
Insufficient samples, possible path obstruction
4
Both Axis Failed
Insufficient samples, possible path obstruction
8
NVM error
Nonvolatile Memory checksum failed
9
ROM error
Read Only Memory checksum failed
10
Maximum Gain
Questionable wind measurements
4.3 Schematics of Connectors
Knowledge of schematics is not necessary for routine installation and
maintenance. Each connector has a small molded dot by pin 1. All of the
schematics show the pinned connectors on the cables. Socketed connectors on
the back of the enclosure are the mirror images of what’s shown.
4.3.1 Sensor Schematics
Schematics of T107 sensors and associated connectors are provided in
FIGURE 4-3 through FIGURE 4-9 for help in troubleshooting.