filter in the cup of water. Remove the filter and allow to air dry before

putting it back on the end of the sensor.

6 months

Replace 034B-ET’s anemometer bearings and reed switch if operating

under harsh conditions, such as constant high winds, blowing dust, and/or

salt spray contamination.

1 year

Replace 034B-ET wind speed (anemometer) bearings (pn 3648). Contact

your local Toro distributor for service.

Replace 034B-ET wind speed (anemometer) reed switch (pn 13764) if

needed. Contact your local Toro distributor for service.

Check calibration of the HMP60-ETS temp/RH probe. Sensor will tend to

drift up over time giving readings higher than 100%. Replace RH chip (pn

9598) if necessary (see FIGURE 4-1 and Section 4.1.4.1, Procedure for

Removing RH Chip).

T107 stations began shipping January 2014 with an updated gill

radiation shield retained with knurled thumb screws, using the

HMP60-ETS Temp/RH sensor. All information in this document

is also pertinent for the HMP50-ET, HMP60-ET, and HMP60-

ETR sensors.

Replace desiccant in enclosure housing as needed.

FIGURE 4-1. Exploded view of the temperature and RH sensor

(adapter not shown)