FIGURE 2-7. Enclosure Spacing Above Pole

2.4 Crossarm and Sensor Installation

Refer to Appendix C.2, Crossarm, for a labeled, exploded view of the

crossarm.

2.4.1 Components

(1) T107 Crossarm with Sensors (see FIGURE 2-6)

(1) Met One 034B or Gill WindSonic Wind Sensor

(1) White Mounting Shaft for 034B or Gill WindSonic

(1) Gill Radiation Shield

2.4.2 Crossarm Installation

Adjust the bolts at the base of the pole to vertically level the top section of the

mounting pole. Install the T107 Sensor Arm after the ET Enclosure is mounted

on the ET Tower. You may need to temporarily remove the communications

option. Mount the sensor arm as shown in FIGURE 2-8 without the wind

sensor attached.