Appendix A: Technical Specifications

104

Back-to-Back – Converteon™ Module Configured for MissingLink™
Test

Figure 50 on page 102 shows a back-to-back configuration for two
Converteon™ modules (Module A and Module B) that has been
configured for the Missing Link Test mode. Refer to “MissingLink™” on
page 44
for configuring the module of the MissingLink™ Test mode.
Module A is connected to an AT-8524M (Switch 1) with a copper cable
and to Module B with a dual fiber cable. Module B is connected to a AT-
8524M (Switch 2) with a copper cable.

Table 31 shows the Link LED status for each of the ports involved when
the cables are connected and disconnected from Module A's ports only.

Table 31. Back-to-Back – Converteon™ Module in MissingLink™ Test Mode

Network

Device

Port

Link

Converteon™ Module Cable Status

All Cables

Connected

Copper Cable

Switch 1 to

Module A -

Disconnected

Module A

Transmit/

Receive

Fiber Cable

Disconnected

Port
LINK
Status

Switch 1

Copper
LK LED

ON

OFF

OFF

Converteon™
Module A

Copper
LK LED

ON

OFF

OFF

Fiber
LK LED

ON

OFF

OFF

Converteon™
Module B

Fiber
LK LED

ON

OFF

OFF

Copper
LK LED

ON

ON

OFF

Switch 2

Copper
LK LED

ON

ON

OFF