Allied Telesis AT-CM70S User Manual

Page 105

Advertising
background image

Converteon Media Converter Line Cards Reference Guide

105

Back-to-Back – Converteon™ Module Configured for Smart
MissingLink Test

Figure 50 on page 102 shows a back-to-back configuration for two
Converteon™ modules (Module A and Module B) that has been
configured for the Smart MissingLink Test mode. Refer to “Smart
MissingLink” on page 45 for co
nfiguring the module of the Link Test mode.
Module A is connected to an AT-8524M (Switch 1) with a copper cable and
to Module B with a dual fiber cable. Module B is connected to a
AT-8524M (Switch 2) with a copper cable.

Table 32 shows the Link LED status for each of the ports involved when
the cables are connected and disconnected from Module A's ports only.

Table 32. Back-to-Back – Converteon™ Module in Smart MissingLink Test Mode

Network

Device

Port

Link

Converteon™ Module Cable Status

All Cables

Connected

Copper Cable

Switch 1 to

Module A -

Disconnected

Module A

Transmit/

Receive

Fiber Cable

Disconnected

Port
LINK
Status

Switch 1

Copper
LK LED

ON

OFF

Blinking

Converteon™
Module A

Copper
LK LED

ON

OFF

Blinking

Fiber
LK LED

ON

Blinking

OFF

Converteon™
Module B

Fiber
LK LED

ON

Blinking

OFF

Copper
LK LED

ON

Blinking

Blinking

Switch 2

Copper
LK LED

ON

Blinking

Blinking

Advertising