Appendix C Service

120

Series N5700 User’s Guide

Command

Errors

(continued)

−141

Invalid character data
Either the character data element contains an invalid character, or the element is not valid.

−144

Character data too long
The character data element contains more than 12 characters.

−148

Character data not allowed
A discrete parameter was received, but a string or numeric parameter was expected.

−150

String data error
Generic string data error

−151

Invalid string data
An invalid character string was received. Check that the string is enclosed in quotation marks.

−158

String data not allowed
A character string was received, but is not allowed for this command.

−160

Block data error
Generic block data error

−161

Invalid block data
The number of data bytes sent does not match the number of bytes specified in the header.

−168

Block data not allowed
Data was sent in arbitrary block format but is not allowed for this command.

−170

Expression error
Generic expression error

−171

Invalid expression data
The expression data element was invalid.

−178

Expression data not allowed
Expression data element was sent but is not allowed for this command.

Execution

Errors

(these errors set Standard Event Status register bit #4)

−200

Execution error
Generic syntax error

−220

Parameter error
A data element related error occurred.

−221

Settings conflict
A data element could not be executed because of the present instrument state.

−222

Data out of range
A data element could not be executed because the value was outside the valid range.

−223

Too much data
A data element was received that contains more data than the instrument can handle.

−224

Illegal parameter value
An exact value was expected but not received.

−225

Out of memory
The device has insufficient memory to perform the requested operation.

−226

Lists not same length
One or more lists are not the same length.

−230

Data corrupt or stale
Possible invalid data. A new reading was started but not completed.