5 Language Reference

78

Series N5700 User’s Guide

*IDN?

This query requests the power supply to identify itself. It returns a
string of four fields separated by commas.

Agilent Technologies
xxxxxA
0
<A.xx.xx>,<A.xx.xx>

Manufacturer
Model number followed by a letter suffix
Zero or serial number if available
Firmware revision, power supply revision

*OPT?

This query requests the unit to identify any installed options. A 0
indicates no options are installed.

*RCL <state>

This command restores the power supply to a state that was
previously stored in memory locations 0 through 15 with the *SAV
command. Note that you can only recall a state from a location that
contains a previously-stored state.

NOTE

All saved instrument states are lost when the unit is turned off.

*RST

This command resets the power supply to a factory-defined state.
This state is defined as follows. Note that *RST also forces an ABORt
command. The *RST settings are as follows:

CAL:STAT Off

[SOUR:]CURR:PROT:STAT

Off

INIT:CONT Off

[SOUR:]VOLT

0

OUTP Off [SOUR:]VOLT:LIM

0

[SOUR:]CURR 0

[SOUR:]VOLT:TRIG 0

[SOUR:]CURR:TRIG 0

[SOUR:]VOLT:PROT

MAXimum

*SAV <state>

This command stores the present state of the power supply to
memory locations 0 through 15.

NOTE

All saved instrument states are lost when the unit is turned off.

*TST?

This query always returns a zero.