Status Commands

Status commands program the power supply’s status registers. As
shown in the following figure, the power supply has three groups of
status registers; Operation, Questionable, and Standard Event. The
Operation and Questionable status groups each consist of the
Condition, Enable, and Event registers and NTR and PTR filters.

LOGICAL

OR

LOGICAL

OR

PON

CME

EXE

DDE

QYE

OPC

0

2

3

4

5

7

1

4

8

16

32

128

1

4

8

16

32

128

EVENT

ENABLE

STANDARD EVENT

STATUS

STATUS BYTE

SERVICE

REQUEST

ENABLE

LOGICAL

OR

SERVICE

REQUEST

GENERATION

8

16

32

128

8

16

32

128

RQS

OPER

MSS

ESB

MAV

QUES

4

5

6

7

UNR

OT

OV

0

4

QUESTIONABLE STATUS

10

CONDITION

LOGICAL

OR

EVENT

ENABLE

PTR/NTR

1

16

1024

1

16

1024

1

16

1024

1

16

1024

3

CONDITION

5

8

PTR/NTR

EVENT

ENABLE

CV

CC

32

256

OC

1

WTG

OPERATION STATUS

PF

2

4

4

2

4

4

2

2

2

INH

9

512

512

512

512

64

10 1024

256

1024

256

1024

256

1024

OUTPUT BUFFER

QUEUE

NOT

EMPTY

Data

Data

Data

*STB?

*SRE<n>
*SRE?

*ESR?

STAT:QUES:COND?

*ESE<n>
*ESE?

STAT:QUES:PTR |:NTR <n>
STAT:QUES:PTR |:NTR ?

STAT:QUES:EVEN?

STAT:QUES:ENAB <n>
STAT:QUES:ENAB

STAT:OPER:COND?

STAT:OPER:EVEN?

STAT:OPER:ENAB <n>
STAT:OPER:ENAB

STAT:OPER:PTR |:NTR <n>
STAT:OPER:PTR |:NTR ?

32

32

32

ERROR QUEUE

QUEUE

NOT

EMPTY

Err

Err

Err

4

4

2

ERROR