Appendix A Specifications

90

Series N5700 User’s Guide

Agilent Models N5741A – N5752A and N5761A – N5772A

Model

N5741A
N5761A

N5742A
N5762A

N5743A
N5763A

N5744A
N5764A

N5745A
N5765A

N5746A
N5766A

N5747A
N5767A

N5748A
N5768A

N5749A
N5769A

N5750A
N5770A

N5751A
N5771A

N5752A
N5772A

Series and Parallel Capability:

Parallel operation

Up to 4 identical units can be connected in master/slave mode with single–wire current balancing

Series operation

Up to 2 identical units can be connected using external protection diodes

Savable states:

In volatile memory

16 (in memory locations 0-15)

Interface Capabilities:

GPIB
LXI Compliance
USB 2.0
10/100 LAN

SCPI - 1993, IEEE 488.2 compliant interface
Class C (only apples to units with the LXI label on the front panel)
Requires Agilent IO Library version L.01.01 and up, or 14.0 and up
Requires Agilent IO Library version L.01.01 and up, or 14.0 and up

Environmental Conditions:

Environment
Operating temp.
Storage temp.
Operating humidity
Storage humidity
Altitude

Indoor use, installation category II (AC input), pollution degree 2
0C to 40C @ 100% load
–20C to 70C
Up to 90% relative humidity (no condensation)
10% to 95% relative humidity (no condensation)
Up to 3000 meters.
Above 2000m, derate the output current by 2%/100m and derate the maximum ambient temperature by 1C/100m.
(For 1500W models from 60V to 600V, derate either the output current or the ambient temperature, but not both.)

Regulatory Compliance:

EMC






Safety

Complies with European EMC Directive for test and measurement products.
● IEC/EN 61326-1
● CISPR 11, Group 1, class A
● AS/NZS CISPR 11
● ICES/NMB-001
Complies with the Australian standard and carries the C-Tick mark.
This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada.
Complies with the European Low Voltage Directive and carries the CE-marking.
Conforms to UL 61010-1 and CSA C22.2 61010-1.

Acoustic Noise Declaration:

Statements provided to comply with requirements of the German Sound Emission Directive, from 18 January 1991:
Sound Pressure Lp <70 dB(A), * At Operator Position, * Normal Operation, * According to EN 27779 (Type Test).
Schalldruckpegel Lp <70 dB(A) * Am Arbeitsplatz, * Normaler Betrieb, * Nach EN 27779 (Typprüfung).

Output Terminal Isolation:

6V to 60V units

No output terminal may be more than +/- 60 VDC from any other terminal or chassis ground

80V to 600V units

No output terminal may be more than +/- 600 VDC from any other terminal or chassis ground

AC Input:

Nominal Input
Input Current 750W
Input Current 1500W
Input Range
Power Factor
Efficiency
Inrush Current

100 – 240 VAC; 50/60Hz
10.5A @ 100 VAC nominal; 5A @ 200 VAC nominal
21A @ 100 VAC nominal; 11A @ 200 VAC nominal
85 – 265 VAC; 47 – 63 Hz.
0.99 at nominal input and rated output power
76% – 87% for 750W units; 77% – 88% for 1500W units
< 25A for 750W units; < 50 A for 1500W units