Supplemental characteristics – Agilent Technologies System DC N5700 User Manual

Page 89

Advertising
background image

Specifications Appendix A

Series N5700 User’s Guide

89

Supplemental Characteristics

Agilent Models N5741A – N5752A and N5761A – N5772A

Model

N5741A
N5761A

N5742A
N5762A

N5743A
N5763A

N5744A
N5764A

N5745A
N5765A

N5746A
N5766A

N5747A
N5767A

N5748A
N5768A

N5749A
N5769A

N5750A
N5770A

N5751A
N5771A

N5752A
N5772A

Output Response Time: (to settle to within 1.0% of the rated output, with a resistive load)

Up,

full

load

0.08s 0.08s 0.08s 0.08s 0.08s 0.08s 0.08s 0.15s 0.15s 0.15s 0.15s 0.25s

Down,

full

load

0.05s 0.05s 0.05s 0.05s 0.08s 0.08s 0.08s 0.15s 0.15s 0.15s 0.15s 0.30s

Down,

no

load

0.5s 0.6s 0.7s 0.8s 0.9s 1.0s 1.1s 1.2s 1.5s 2.0s 3.0s 4s

Command Response Time: (add this to the output response time to obtain the total programming time)

55

ms

Remote Sense Compensation:

Volts/load

lead

1V 1V 1V 1V 1.5V 2V 3V 4V 5V 5V 5V 5V

Over-voltage Protection:

Range

0.5-7.5V 0.5-10V 1-15V 1-24V 2-36V 2-44V 5-66V 5-88V 5-110V 5-165v 5-330V 5-660V

Accuracy

0.06V 0.08V 0.125V 0.20V 0.30V 0.40V 0.60V 0.80V 1V 1.5V 3V 6V

Output Ripple and Noise: (

From 5Hz-1MHz, at 10% to 100% of output voltage at full load (for 6V units from 33% to 100% of output voltage)

CC

rms

750W

200mA

180mA

120mA 76mA 63mA 48mA 38mA 29mA 23mA 18mA 13mA 8mA

CC

rms

1500W

360mA

330mA

240mA 152mA 125mA 95mA 75mA 57mA 45mA 35mA 25mA 12mA

Programming Resolution:
Measurement Resolution:

Voltage

0.72mV

0.96mV 1.5mV 2.4mV 3.6mV 4.8mV 7.2mV 9.6mV 12mV 18mV 36mV 72mV

Current

750W

12mA 10.8mA 7.2mA 4.56mA

3mA 2.3mA 1.5mA 1.14mA 0.9mA 0.6mA 0.3mA 0.156mA

Current 1500W

21.6mA 19.8mA 14.4mA 9.12mA

6mA 4.6mA 3mA 2.28mA 1.8mA 1.2mA 0.6mA 0.312mA

Front Panel Display Accuracy: (4 digits; +% of rated output; 1 count)

Voltage

30mV 40mV 62.5mV 100mV 150mV 200mV 300mV 400mV 500mV 750mV 1.5

V 3

V

Current 750W

500mA 450mA 300mA 190mA 125mA 95mA 62.5mA 47.5mA 37.5mA 25mA 12.5mA 6.5mA

Current

1500W

900mA 825mA 600mA 380mA 250mA 190mA 125mA 95mV 75mA 50mA 25m 13mA

Temperature Drift: (over 8 hours, after a 30 minute warm-up, with constant line, load, and temperature)

Voltage

3mV

4mV 6.25mV 10mV 15mV 20mV 30mV 40mV 50mV 75mV 150mV 300mV

Current

750W

50mA 45mA 30mA 19mA 12.5mA 9.5mA 6.25mA 4.75mA 3.75mA 2.5mA 1.25mA 6.5mA

Current

1500W

90mA

82.5mA 60mA 38mA 25mA 19mA 12.5mA 9.5mA 7.5mA 5mA 2.5mA 1.3mA

Temperature Coefficient: (after a 30 minute warm-up)

Voltage and Current

100PPM/°C from rated output voltage or current

Analog Programming and Monitoring:

Vout voltage

0 - 100%, 0-5V/10V, user selectable, Accuracy & linearity = +/-0.5% of rated Vout

Iout voltage

0 - 100%, 0-5V/10V, user selectable, Accuracy & linearity = +/-1% of rated Iout

Vout resistance

0 - 100%, 0-5k/10k, user selectable, Accuracy & linearity = +/-1% of rated Vout

Iout resistance

0 - 100%, 0-5k/10k, user selectable, Accuracy & linearity = +/-1.5% of rated Iout

Iout monitor

0-5V/10V, user selectable, Accuracy = 1%

Vout monitor

0-5V/10V, user selectable, Accuracy = 1%

On/Off control

Electrical voltage; 0-6V/2-15V or dry contact, user selectable logic

PS OK signal

5V = OK; 0V = FAIL; 500 series resistance

CV/CC signal

CV = TTL high (4-5V) source current 10mA; CC = TTL high (4-5V) sink current 10mA

Enable/Disable

Dry contact. Open=Off, Short=On. Maximum voltage at terminal= 6V.

Advertising