Manual Updates

11/08/07 The following documents the differences between front
panel operation of the LXI-compliant units and the pre-LXI units.

LXI-compliant units

(see page 10 for additional details)

Pre-LXI units

OCP/488

LAN

OUT ON

DC AMPS

CURRENT

10

11

12

9

CC

OCP

REM

OUT ON

DC AMPS

CURRENT

10

11

12

9

CC

9 – LAN
button

View address: Press LAN to view the IP
and Ethernet address.
Reset address: Press and hold the LAN
button for three seconds. Pressing the
LAN button again while “LAn rES” is
displayed resets the LAN configuration
to the factory-shipped settings.

9 – REM
button

Mode function: Press REM to put the
unit into local mode. This function is
not available in LXI compliant units.
Address function: Selects the GPIB
address. Press and hold the REM
button for three seconds to set the
address with the Voltage knob.

10 – LAN
indicator

When lit, indicates that the LAN has
been configured and is operating
normally. When blinking, identifies the
unit for which the indicator has been set
to blink by the unit’s Web home page.

10 – REM
indicator

When lit, indicates that the unit is in
Remote mode. This function is not
available in LXI compliant units.

11 – OCP/488
button

Enable OCP: Press OCP/488 to turn
over-current protection (OCP) on. Press
again to turn OCP off.
Reset OCP: When an over-current
protection event occurs, press the OUT
ON button to enable the output and re-
arm over-current protection.
GPIB address: Press and hold the
OCP/488 button for three seconds to set
the address with the Voltage knob.

11 – OCP
button

Enable function: Press OCP to turn
over-current protection (OCP) on.
Press again to turn OCP off.
Reset OCP: When an over-current
protection event occurs, press the
OUT ON button to enable the output
and re-arm over-current protection.

12 – OCP
indicator

When lit, indicates that over-current
protection is enabled or on.

12 – OCP
indicator

When lit, indicates that over-current
protection is enabled or on.

2/18/09 On page 28, information has been added under “Grounding
the Output”.

9/28/10 On page 28, information has been added about battery
charging. The warnings on pages 28 and 30 have been updated.