Using the setup utility – Agilent Technologies System DC N5700 User Manual

Page 56

Advertising
background image

4 Operating the Power Supply Remotely

56

Series N5700 User’s Guide

Factory-shipped LAN Settings

The factory-shipped LAN settings documented in the following table
are optimized for connecting your power supply to a site network.
They should also work well for other network configurations.

The factory-shipped settings can be restored by pressing and holding
the front panel LAN button for three seconds. Pressing the LAN
button again while the message “LAn rES” is displayed resets the
LAN settings.

Factory-shipped non-volatile LAN settings

Get IP Address

Automatic

Dynamic DNS naming service

Enabled

IP Address

169.254.57.0

NetBIOS naming service

Enabled

Subnet Mask

255.255.0.0

Domain name

Blank

Default Gateway

0.0.0.0

TCP keepalive

Enabled

Obtain DNS server from DHCP

Enabled

TCP keepalive seconds

1800

DNS server

Blank

Ethernet Auto-negotiation

Enabled

Host name

A-N57xxA-xxxxx

Ping server

Enabled

Web

password

Blank

Using the Setup Utility

A Setup utility that lets you configure the LAN settings of your
instrument is provided on the Product Reference CD-ROM included
with this manual. Install and run this Setup utility if you cannot
configure the LAN interface as previously described in this section.

1 Connect your power supply to your computer using either the

USB interface or the GPIB interface as previously described.

2 Install the Setup utility on your computer. Run the Setup utility

by clicking Start|Programs|Agilent|N5700 Setup Utility.

3 Configure the following LAN address parameters. These are

located under the Settings tab. For a description of these
parameters, refer to the previous section.