3) display items – APC AXFA11G User Manual

Page 21

Advertising
background image

IM 01E20C01-01E

5-2

5. BASIC OPERATING PROCEDURES

(3) Display items

Displayed items and

reversed-character indication

T0501.EPS

Displays the instantaneous flow rate for the span as a percentage.

Displays the actual reading for instantaneous flow rate.

Displays the instantaneous flow rate for the span as a current output value.

Displays the instantaneous flow rate for the span as a percentage
using bar graph.

Displays the totalized value for flow rate in the forward direction.

Displays the totalized value for flow rate in the reverse direction.

Displays the differential totalized value for flow rate between
forward totalization and reverse totalization.

Display the tag number (using up to 16 characters).

Displays the adhesion condition in the form of a bar graph.
(See the description for parameters K10 through K15 from
Chapter 6: Parameter Description for more details.)

Displays the communication type.

Content

Disp Select1

Disp Select2
Disp Select3

Instantaneous flow rate: %

Actual instantaneous flow rate

Instantaneous flow rate: mA

Bar graph indicating
instantaneous flow rate

Totalized forward-direction flow rate

Totalized reverse-direction flow rate

Totalized differential flow rate

Tag number

Diagnosis of electrode adhesion

Communication

FR

FR

FR

None

FTL

RTL

DTL

TAG

ADH

COM

(4)