Programming control, What can be programmed, Programmable options available – Alliance Laundry Systems PHM1263R User Manual

Page 13

Advertising
background image

11

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming Control

What Can Be Programmed?

This feature allows the owner to program cycle
information and other features by using the keypads.
The control must have the Manual Programming
Mode enabled, which is the factory default. This mode
can only be turned “oFF” and “on” by using an
external device. Refer to this section when programming
the control.

This section offers a detailed description of all available
programmable options.

Each description includes instructions on when and
why the option might be used and, more importantly,
how to program the option.

For more advanced users, a quick reference list (refer
to Table 1) of the options available through the Manual
Programming Mode is available. Programming
Flowcharts (refer to Figures Figure 2-Figure 6) are
located on the following pages.

NOTE: The letters and numbers in the Option
Display column of the Programmable Options List
are what will be shown in the display when that
option is selected.

Programmable Options Available

Option

Number

Option

Display

Description

Default

Value

Value Range

1

dCYC

Default Cycle

“Cy05”*

“Cy01”-“Cy30”*

2

AUd

Audio Signal

“29”*

“0”-“31”*

3

Err-”

Errors

a.

“E FL”

Fill Errors

“on”

“on”/“oFF”

b.

“E dr”

Drain Error

“on”

“on”/“oFF”

c.

“E Ub”

Unbalance Error Display

“on”

“on”/“oFF”

d.

“E oP”

Open Thermister Error Display

“on”

“on”/“oFF”

e.

“E SH”

Shorted Thermistor Error Display

“on”

“on”/“oFF”

f.

“E Ht”

Heat Error Display (Heater only)

“on”

“on”/“oFF”

g.

“LEr-”

Water Leak Detection Error

1.

“LEr1”

Water Leak Detection During a Machine Cycle
(On/Off)

“oFF”

“on”/“oFF”

2.

“LEr2”

Water Leak Detection Day of Week Enable

“127”*

“0”-“127”*

3.

“LEr3”*** Number of Cycles Between Water Leak

Detection During a Machine Cycle

“0”

“0”-“127”

h.

“E Sd”

Slow Drain Detection

“oFF”

“on”/“oFF”

4

Cy--”

Cycle Programming

Refer to Cycle Chart for default cycle information

a.

AgIt

Cycle Agitate

1.

tyPE

Agitate Type

**

“1”-“4”*

2.

ASPd

Agitate Speed (VFD only)

**

“Lo”/“rEg”*

b.

Segx

(1-8)

Cycle Segment Programming

1.

“SgEn”

Segment Enable/Disable

**

“on”/“oFF”

2.

FILL

Fill Step

a.

“FLEn”

Fill Step Enable/Disable

**

“on”/“oFF”

b.

“FLEU”

Fill Level

**

“HI”/“nEd”/“Lo” or 1-30

Table 1 (continued)

Advertising