Programming Control

29

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming Drain Step

1. When “drAn” appears in the display, press the

START (enter) keypad. The current status will be
displayed.

2. Press the #3 ( ) or the #6 ( ) keypad to change

the current status.
“on”

= Drain step is enabled

“oFF” = Drain step is disabled

NOTE: Drain must be enabled to activate Extract
step.

3. Press the START (enter) keypad when the

desired status appears in the display. The next
Cycle Segment option, “SPIn”, will appear in the
display.

NOTE: To program “SPIn” (Extract Step),
continue to next Cycle Segment option. To program
other options press the #3 ( ) or the #6 ( ) keypad
and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to
Ready Mode.

Programming Extract Step

1. When “SPIn” appears in the display, press the

START (enter) keypad. The first Extract step
programming option will appear in the display.

2. Press the #3 ( ) or the #6 ( ) keypad to scroll

through the programmable Extract step options.
Refer to Table 9.

NOTE: Extract Step “

SPEn

” must be enabled to

scroll through all Extract step options.

3. Press the START (enter) keypad when the

desired option appears in the display. The current
status/value will appear in the display. Refer to
Table 9.

M

4. Press the #3 ( ) or the #6 ( ) keypad to change

the current status/value.

5. Press the START (enter) keypad when the

desired status/value appears in the display.

NOTE: To program “Cnin” (Cycle Time Display),
continue to next Cycle Segment option. To program
other options press the #3 ( ) or the #6 ( ) keypad
and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to
Start Mode.

>

<

>

<

>

<

Extract

Step

Description

Status/Value

“SPEn”

Extract Step

Enable/
Disable

“on”/“oFF”

“SSEC”

Extract

Seconds

0-59

“SnIn”

Extract

Minutes

Intermediate Extract:
Minimum
Step Time = 30 seconds
Maximum
Step Time = 3:59 minutes

Final Extract:
Minimum
Step Time = 30 seconds
Maximum
Step Time = 9:59 minutes

“SSPd” Extract Speed

(G) (Design 1

and 2 VFD

models only)

1 = very low speed (60)
2 = low speed

(L-speed = 100;
M-speed = 120)

3 = medium speed

(L-speed = 100;
M-speed = 180)

Extract Speed
(G) (Design 4

models only)

1 = very low speed (27)

(L and M-speed)

2 = low speed (100)

(L and M-speed)

3 = medium speed (200)

(M-speed)

Table 9

>

<

>

<