Programming Control

F8208801

28

Programming Supply Step

1. When “SUPL” appears in the display, press the

START (enter) keypad. The first Supply step
programming option will appear in the display.

2. Press the #3 ( ) or the #6 ( ) keypad to scroll

through the programmable Supply step options.
Refer to Table 7.

NOTE: Supply Step “SUEn” must be enabled to
scroll through all Supply Step options.

3. Press the START (enter) keypad when the

desired option appears in the display. The current
status value will appear in the display. Refer to
Table 7.

4. Press the #3 ( ) or the #6 ( ) keypad to change

the current status/value.

5. Press the START (enter) keypad when the

desired status/value appears in the display. The
next Supply step option will appear in the
display.

NOTE: To program “AgSt” (Agitate Step),
continue to next Cycle Segment option. If in the
Dispenser Options or Supply Duration
programming option, press the #5 (<) keypad first.
To program other options, press the #3 ( ) or the #6
( ) keypad and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to
Ready Mode.

Programming Agitate Step

1. When “AgSt” appears in the display, press the

START (enter) keypad. The first Agitate step
programming option will appear in the display.

2. Press the #3 ( ) or the #6 ( ) keypad to scroll

through the programmable Agitate step options.
Refer to Table 8.

NOTE: Agitate Step “AgEn” must be enabled to
scroll through all Agitate step options.

3. Press the START (enter) keypad when the

desired option appears in the display. The current
status/value will appear in the display. Refer to
Table 8.

4. Press the #3 ( ) or the #6 ( ) keypad to change

the current status/value.

5. Press the START (enter) keypad when the

desired status/value appears in the display. The
next Agitate step option will appear in the
display.

NOTE: To program “drAn” (Drain Step), continue
to next Cycle Segment option. To program other
options, press the #3 ( ) or the #6 ( ) keypad and
refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to
Start Mode.

Supply

Step

Description

Status/Value

“SUEn”

Supply Step

Enable/Disable

“on”/“oFF”

“dISP”

Dispenser Options

Press START (enter) to

access options

“S1”

Supply #1

“on”/“oFF”

“S2”

Supply #2

“on”/“oFF”

“S3”

Supply #3

“on”/“oFF”

“S4”

Supply #4

“on”/“oFF”

“SdUr”

Supply Duration

Press START (enter)

to access options

“SEC”

Seconds

0-59

“nIn”

Minutes

0-9

Table 7

>

<

>

<

>

<

Agitate

Step

Description

Status/Value

“AgEn”

Agitate Step

Enable/Disable

“on”/“oFF”

“AdUr”

Agitate Duration

(in minutes)

1-30 Minutes for

agitate types 1 or 2

1-180 Minutes for

agitate types 3 or 4

(Refer to Cycle Agitate)

“HEAt”

Heat in Agitate

(If heater is present)

“oFF”, 1 or 2

1 = To Target

2 = Maintain

Table 8

>

<

>

<

>

<