Alliance Laundry Systems PHM1263R User Manual

Page 47

Advertising
background image

Testing Machine and Electronic Control Functions

45

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Diagnostic (Testing) Mode – Quick Reference Chart

Test Number

Diagnostic Mode

Display

“d001”

Front End Control Software Version # Test

S xx”

“d002”

Output Board Control Software # Test

o xx”

“d003”

Output Board Water Level Sensor Trim Value

txxx”

“d004”

Top Cover Opening Test

A oP” or

A CL”

“d009”

Door Switch Input Test

drCL” or “drOP”

“d010”

Door Lock Input Test

drUL” or “drLO”

“d011”

Show Fill Time Test

Fxxx”

“d012”

Show Drain Time Test

dxxx”

“d013”

Temperature Sensor Display Test

“xxx

F” or “xxxC”

“d014”

Start Pulse Test

Stxx”

“d015”

VFD Balance Input Test (Design 1 and 2)

bAoP” or “bACL”

“d016”

24 VAC Switch Input Test (Design 1 and 2)

ACoP” or “ACCL”

“d017”

VFD Drive Fault Input Test (Design 1 and 2)

dFoP” or “dFCL”

“d018”

Frame Balance Switch Input Test

FSoP” or “FSCL”

“d019”

VFD Balance Weight Test (Design 1 and 2)

bAL”

Drive DC Bus Display Test (Design 4)

dCb”

“d020”

Water Purge Test

PUrg”

“d021”

Water Leak Detection Test

Ld”

“d022”

Drive Software Version Number (Design 4)

drxx”

“d023”

Drive Parameter Table Version Number
(Design 4)

dPxx”

“d024”

Drive Type Value (Design 4)

dt x”

Table 13

Advertising