Alliance Laundry Systems PHM1263R User Manual

Page 47

Advertising
background image

Testing Machine and Electronic Control Functions

45

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Diagnostic (Testing) Mode – Quick Reference Chart

Test Number

Diagnostic Mode

Display

“d001”

Front End Control Software Version # Test

“

S xx”

“d002”

Output Board Control Software # Test

“

o xx”

“d003”

Output Board Water Level Sensor Trim Value

“

txxx”

“d004”

Top Cover Opening Test

“

A oP” or

“

A CL”

“d009”

Door Switch Input Test

“

drCL” or “drOP”

“d010”

Door Lock Input Test

“

drUL” or “drLO”

“d011”

Show Fill Time Test

“

Fxxx”

“d012”

Show Drain Time Test

“

dxxx”

“d013”

Temperature Sensor Display Test

“xxx

F” or “xxxC”

“d014”

Start Pulse Test

“

Stxx”

“d015”

VFD Balance Input Test (Design 1 and 2)

“

bAoP” or “bACL”

“d016”

24 VAC Switch Input Test (Design 1 and 2)

“

ACoP” or “ACCL”

“d017”

VFD Drive Fault Input Test (Design 1 and 2)

“

dFoP” or “dFCL”

“d018”

Frame Balance Switch Input Test

“

FSoP” or “FSCL”

“d019”

VFD Balance Weight Test (Design 1 and 2)

“

bAL”

Drive DC Bus Display Test (Design 4)

“

dCb”

“d020”

Water Purge Test

“

PUrg”

“d021”

Water Leak Detection Test

“

Ld”

“d022”

Drive Software Version Number (Design 4)

“

drxx”

“d023”

Drive Parameter Table Version Number
(Design 4)

“

dPxx”

“d024”

Drive Type Value (Design 4)

“

dt x”

Table 13