Following is a list of possible error codes for an
electronic control. Errors beginning with “EI” refer to
external device Infra-red communication errors. All
other errors refer to machine errors.

Display

Description

Cause/Corrective Action

EI01

Transmission Failure

Communication failure. Re-aim external device and try again.

EI02

Time-out Error

Communication failure. Re-aim external device and try again.

EI03

Invalid Command Code

Communication successful, but the command was not valid
for this machine type, or the control could not perform the
command in its current mode of operation. Ensure data is for
current machine type and control is in correct mode.

EI04

Expecting Upload Request

Communication failure. Re-aim external device and try again.

EI05

Invalid or Out-of-Range Data

The value in at least one of the programming options is
invalid or out of range. Recheck the programming option’s
value and try again.

EI09

CRC-16 Error

Communication failure. Re-aim external device and try again.

EI0A

Framing Error

Communication error. Re-aim external device and try again.

EI0C

Time-out Exceeded

Communication error. Re-aim external device and try again.

EI0E

Encryption Error

Communication error. Re-aim external device and try again.
If the problem persists, check that the security code is correct.

EI0F

Infra-red Disabled

Communication failure or infra-red is disabled. Manually
enable infra-red on control or re-aim external device and try
again.

E FL

Fill Error

Programmed water level not reached within 10 minutes (or
other programmed length of time) in any fill agitate cycle.
End cycle. Power down machine to clear.

E SP

SPI Communications Error

Front End control cannot communicate with output board.
Power down the machine, power up and try again.

E dL

Door Lock Error

Door does not lock immeadiately upon closing (open and
reclose door) or doesn’t unlock 5 seconds after cycle
completion. Power down machine and retry.

E do

Door Open Error

Control detects door open. Caused by pulling on door while
locked or about to lock. Correct inoperative door locking
system. End cycle. Power down machine to clear.

E Ub

Unbalance Error

Unable to balance load. Redistribute load and run cycle.

door

Door Open Indicator

Door is not closed in Start Mode. If door is closed, check for
improper wiring or faulty door switch.