Slow drain detection adjust “sdad – Alliance Laundry Systems PHM1263R User Manual

Page 38

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming Control

F8208801

36

16. Slow Drain Detection Adjust

“SdAd”

This option allows the owner to increase or decrease
the slow drain detection threshold by adding additional
seconds to the threshold value. When enabled it
increases the time before a Slow Drain Error will
occur.

How to Program the Pause/Resume Mode

1. Control must be in Manual Mode. Refer to

Entering the Manual Mode.

2. Press the #3 ( ) or the #6 ( ) keypad until

“Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.

3. Press the #3 ( ) or the #6 ( ) keypad to scroll

through the programmable options until “SdAd”
appears in the display.

4. When “SdAd” appears in the display, press the

START (enter) keypad. The current Slow Drain
Detection Adjust Value will appear in the display.
“on” = Option Enabled
“oFF” = Option Disabled

5. Press the #3 ( ) or the #6 ( ) keypad to change

the current value.

6. Press the START (enter) keypad when the

desired value appears in the display. The next
option, “rtc”, will appear in the display.

NOTE: To program “rtc” (Set Real-Time Clock),
refer to option 17
. To program other options, refer
to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to
Start Mode.

>

<

>

<

>

<