Programming Control

F8208801

30

Programming Cycle Time Display

NOTE: This option is not available on Software
Version 1.

NOTE: This programmable option (Cnin) will only
appear if the Programmable Cycle Time Display
option (PCtd) has been enabled.

1. When “Cnin” appears in the display, press the

START (enter) keypad. The current status will be
displayed.

2. Press the #3 ( ) or the #6 ( ) keypad to change

the current value. The cycle time display can be
set from 0 to 255 minutes.

3. Press the START (enter) keypad when the

desired value appears in the display.

NOTE: To program another cycle, repeat Cycle
Programming steps. To program other options
press the the #3 ( ) or the #6 ( ) keypad and refer
to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to
Start Mode.

5.

Number of Balance Retries
“bALr” (Variable Frequency
Drives Only)

This option allows the owner to program how many
times the control will retry balancing the load before
moving into Extract step.

How to Program Number of Balance
Retries

1. Control must be in Manual Mode. Refer to

Entering the Manual Mode.

2. Press the #3 ( ) or the #6 ( ) keypad until

“Prog” appears in the display. Press the START
(enter) keypad, and “dCYC” will appear in the
display.

3. Press the #3 ( ) or the #6 ( ) keypad to scroll

through the programmable options until “bALr”
appears in the display.

4. When “bALr” appears in the display, press the

START (enter) keypad. The current value will
appear in the display.

5. Press the #3 ( ) or the #6 ( ) keypad to increase

or decrease the current value.

NOTE: The number of balance retries can be set
from 1-7. Design 1 and 2 default number of balance
retries is 3 and Design 4 default number of balance
retries is 1.

6. Press the START (enter) keypad when the

desired value appears in the display. The next
option, “IrA”, will appear in the display.

NOTE: To program “IrA” (IR Access [on/off]),
refer to option 6
. To program other options, refer to
the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to
Start Mode.

>

<

>

<

>

<

>

<

>

<

Advertising