How to Program Cycle Segment “SEg1”

There are eight programmable cycle segments. Within
each segment, there are several programmable options.

1. Press the #3 ( ) or the #6 ( ) keypad to scroll

through the eight programmable Cycle Segments
until the desired segment appears in the display.

2. When the desired segment appears in the display,

press the START (enter) keypad. “SgEn”
(Segment Enable/Disable) will appear in the
display.

3. Press the #3 ( ) or the #6 ( ) keypad to scroll

through the Cycle Segment programmable
options.

NOTE: If the Segment Enable/Disable is
programmed “OFF”, the other Cycle Segment
programming options can’t be accessed.

4. Press the START (enter) keypad when the

desired Cycle Segment programmable option
appears in the display.

Programming Segment Enable/Disable

1. When “SgEn” appears in the display, press the

START (enter) keypad. The current Segment
Enable/Disable status will appear in the display.
“on” = Segment is enabled
“oFF” = Segment is disabled

2. Press the #3 ( ) or the #6 ( ) keypad to change

the current status.

NOTE: If the Segment Enable/Disable is
programmed “oFF”, the other Cycle Segment
programming options can’t be accessed.

3. Press the START (enter) keypad when the

desired status appears in the display. The next
Cycle Segment option, “FILL”, will appear in the
display.

NOTE: To program “FILL” (Fill Step), continue to
next Cycle Segment option. To program other
options, press the #3 ( ) or the #6 ( ) keypad and
refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to
Start Mode.

Programming Fill Step

1. When “FILL” appears in the display, press the

START (enter) keypad. The first Fill step
programming option will appear in the display.

2. Press the #3 ( ) or the #6 ( ) keypad to scroll

through the programmable Fill step options.
Refer to Table 6.

NOTE: Fill Step “FLEn” must be enabled to scroll
through all Fill Step options.

3. Press the START (enter) keypad when the

desired option appears in the display. The current
status will appear in the display. Refer to Table 6.

4. Press the #3 ( ) or the #6 ( ) keypad to change

the current status.

5. Press the START (enter) keypad when the

desired status appears in the display. The next
Fill step option will appear in the display.

NOTE: To program “SUPL” (Supply Step),
continue to next Cycle Segment option. To program
other options, press the #3 ( ) or the #6 ( ) keypad
the and refer to the appropriate section.

How to Exit Programming Feature

Press the #5(<) keypad until the control returns to
Start Mode.

>

<

>

<

>

<

>

<

Fill Step

Description

Status

“FLEn”

Fill Step

Enable/Disable

“on”/”oFF”

“FLEU”

Fill Level

“HI” = high level

“nEd” = medium level

“Lo” = low level

“1-30”

“tEnP”

Fill Temperature

“CoLd” = Cold

“UArn” = Warm

“Hot” = Hot

(35°F-194°F [2°C-90°C])

Table 6

>

<

>

<

>

<