Manual programming flowchart (2 of 3), Programming control, Figure 4 – Alliance Laundry Systems PHM1263R User Manual

Page 18

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming Control

F8208801

16

Manual Programming Flowchart (2 of 3)

PHM1487R

Figure 4

PHM1487R

(continued)

(continued)

(continued)

(continued)

“SUPL” - Program supply step options

“dISP” Dispenser Options:

Press START (enter) to access options

“SdUr” Supply Duration:

Press START (enter) to access options

“AdUr” - Agitate Duration (min):

“1” - “30” (for agitation types 1 or 2) or

“1” - “180” for agitation types 3 or 4

“AgSt” - Program agitate step options

“drAn” - Enable/disable drain step

“SPIn” - Program extract step options

“Cnin” - Programmable

Cycle Time Display

in Minutes: "0" - "255"

Option available on Software

Version 2 or later

“SUEn” - Supply Step Enable/Disable:

“on” = Enabled

“oFF” = Disabled

“AgEn” - Agitate Step

Enabled/Disabled:

“on” = Enabled

“oFF” = Disabled

“SSEC” - Extract Seconds:

“0” - “59”

“SPEn” - Extract Step

Enabled/Disabled:

“on” = Enabled

“oFF” = Disabled

“HEAt” - Heat in Agitate

(heat present only):

“oFF” = Disabled

“1” = To Target

“2” = Maintain

“S3” -

Supply #3:

“on” = Enabled

“oFF” = Disabled

“S2” -

Supply #2:

“on” = Enabled

“oFF” = Disabled

“S4” - Supply #4:

“on” = Enabled

“oFF” = Disabled

Drain Step:

“on” = Enabled

“oFF” = Disabled

“SEC” - Seconds:

“0” - “59”

“nIn” - Minutes:

“0” - “9”

“S1” -

Supply #1:

“on” = Enabled

“oFF” = Disabled

“SnIn” - Extract Minutes:

“30” - “3.59”: Intermediate Step

“30” - “9:59”: Final Step

“SSPd” Extract Speed (G)

(Design 1 and 2 VFD models only):

1 = Very Low Speed (60)

2 = Low Speed

(L - Speed = 100;
M - Speed = 120)

3 = Medium Speed

(L - Speed = 100;

M - Speed = 180)

“SSPd” Extract Speed (G) (Design 4 models only)

1 = Very Low Speed (27)
2 = Low Speed (100)
3 = Medium Speed (200)
(M-speed only)

Advertising