Testing Machine and Electronic Control Functions

F8208801

50

Production Test Cycle Quick Reference Chart

Display

Test Cycle Step

Comments

“S xx”

FEC Control Software
Version

xx is the software version number.

“o xx”

Output Board Software
Version

xx is the software version number.

“Ct 3”

Control Type

xx is the control type.

“oPL”

Control Type

OPL.

“USA”

Control Type

Domestic

“drAn” or “PUnP”

Drain Type

Drain or Pump.

“tEnP”

Temp Sensor

Step skipped if not Temperature Sensor-equipped.

“HEAt”

Heater

Step skipped if not heater-equipped.

“rot”

Rotation Sensor

Step skipped if not Rotation Sensor-equipped.

“L dC” or “L AC”

Door Lock Type

“L dC” if 24 VDC lock or “L AC” if 240 VAC unlock solenoid.

“droP” or “drCL”

Door Status

Door open or closed.

“drUL” or “drLo”

Door Lock Status

Door will lock.

“8.8.8.8.” + all LEDs

Display Test

All display elements are lit.

“PAxx” where xx = 1
through 12

Keypad Test step

Advance after all keypads are pressed.

“A xx”

Top Cover Switch Test

xx is either “CL” for closed or “oP” for open.

“Cxxx” or “Pxxx”

Machine Type/Size

“drxx”

Drive Software Version
Number

xx is the drive software version number. Design 4 models only.

“dPxx”

Drive Parameter Table
Version Number

xx is the drive parameter table version number. Design 4 models
only.

“dt x”

Drive Type Value

xx is the drive type value. Design 4 models only.

“HFIL”

Hot Fill to Low Level

All water outputs turned off when Low Level reached.

“CFIL”

Cold Fill to Low Level

All water outputs turned off when Low Level reached.

“bFIL”

Warm Fill to Low Level

All water outputs turned off when Low Level reached.

“bFIH”

Warm Fill to High Level

All water outputs turned off when High Level reached.

“S1”

Supply #1

“S2”

Supply #2

“S3”

Supply #3

“S4”

Supply #4

Table 16 (continued)