A. Start-up via digital inputs/outputs

A-6

Festo P.BE-SPC11-SYS-EN en 1406e

A.2.1 Setting time-dependency diagram parameters

I7: {/-

1
0

1
0

I1...4:
Po.1...4

1
0

1
0

I8: Remote

1
0

I6: Enter

min. 2 s

1

2

3

I5: +/}

1
0

1

2

99

1

2

n

4

min. 20 ms

min. 20 ms

min. 20 ms

min.
20 ms

O5:
Error/Ready *)

*)

Function of the O5 output can be configured (see chapter 4.2.3); Error (factory setting) or Ready

1

Activate modification mode

2

Reset parameter A to 0

3

Set parameter value A

4

Confirm parameter value A
(switch-on time min. 2 s)

Fig. A/2: Set time-dependency diagram parameter A

After confirmation of the parameter value A, the next para-
meter can be set (see Fig. A/1). After confirmation of the last
parameter, the teach procedure is simultaneously initiated
and can then be started (see Fig. A/3).