3. Installation

3-8

Festo P.BE-SPC11-SYS-EN en 1406e

Proportional directional control valve ( 5 )

Arrange the tubing between the valve (MPYE-5-...) and the
drive symmetrically.

Recommendation for linear drives and drives with piston rod:
tubing length = cylinder length.

The diagram below shows as an example the tubing of a
cylinder with an MPYE-5-... when an SPC11 is used.

1

2

1

Proportional directional control valve type MPYE-5-...-...

2

Service unit with 5 μm filter, without lubricator

Fig. 3/2: Pneumatic circuit diagram

Fit the valve in accordance with the operating instructions
supplied with the valve.