2 pre-parameterising in the office, 1 parameters a, c and s, 2 parameters l and r (only with type spc11-inc) – Festo Контроллер крайних положений SPC11 User Manual

Page 66

Advertising
background image

4. Commissioning

4-8

Festo P.BE-SPC11-SYS-EN en 1406e

4.2

Pre-parameterising in the office

4.2.1 Parameters A, C and S

The permitted values of the parameters A, C, and S for the
drive you are using can be found in the appropriate axis-
specific supplement.

4.2.2 Parameters L and r (only with type SPC11-INC)

The parameters L and r are only queried when incremental
path measuring systems are used (e.g. positioning drive
DNCI-...-... in connection with type SPC11-INC).

With incremental path measuring systems, the SPC11
requires the following information:

Nominal stroke length (L) of the drive (see type plate)

Offset axis zero point (r) – offset between the end position
P.01 and the axis zero point (see Fig. 4/2).

1

Axis zero point
(piston rod run in

2

Offset axis zero
point (r)

3

Fixed stop
(here for end
position P.01)

1

2

3

P.01

P.02

Fig. 4/2: Reference points for incremental path measuring systems with SPC11-INC

Advertising