4 behaviour on stopping via i4 – Festo Контроллер крайних положений SPC11 User Manual

Page 72

Advertising
background image

4. Commissioning

4-14

Festo P.BE-SPC11-SYS-EN en 1406e

4.2.4 Behaviour on stopping via I4

The drive can be stopped via Input I4 if the o-parameter is
configured accordingly.

Possible conditions after stop signal via input I4

Please note

Stop time

Condition after stop

Display

Teach procedure

– Drive is uncontrolled.
– Output O4 supplies 1-signal.

Restart teach procedure
(by Teach button/input)

Reference travel

Restart reference travel
to P.01 or P.02

Teaching of P.03

– Drive is controlled.
– Output O4 supplies 1-signal.

Continue teaching of
P.03

Operation

– Drive is controlled.
– Output O4 supplies a 1-signal

if the drive is stopped.

Continue operation

1

Resetting I4 triggers
a command to stop
the drive according to
the configured o-
parameter

2

O4 is set as soon as
the drive has stopped

3

When I4 is set, the
current actual posi-
tion is used as the
reference position

The axis moves

Stop input I4

Stop output O4

Display

Yes

No

1

0

1

0

1

0

1

2

3

Fig. 4/3: Stopping sequence diagram

Advertising